Evaluation of the Accuracy of Spectral Calibration Light Source on Spectral Radiance Acquired by the Greenhouse-Gases Absorption Spectrometer-2 (GAS-2)

Author:

Li Shizhao1234ORCID,Cheng Long12,Yang Hongchun12ORCID,Ding Lei1234,Wang Xianghua12

Affiliation:

1. Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China

2. Key Laboratory of Infrared System Detection and Imaging Technology, Chinese Academy of Sciences, Shanghai 200083, China

3. University of Chinese Academy of Sciences, Beijing 100049, China

4. School of Information Science and Technology, ShanghaiTech University, Shanghai 201210, China

Abstract

Monitoring global greenhouse gas concentration information via satellite remote sensing has become a critical area of research to support the further understanding of global carbon emissions. The Greenhouse-gases Absorption Spectrometer-2 (GAS-2) is being developed as the primary payload of the Fengyun-3H (FY-3H), which will be launched in 2024. Achieving high-precision mesurements of greenhouse gases requires precise spectral calibration. However, currently, there is no method for assessing the detection accuracy of GAS-2 using spectral calibration light sources, and quantitative studies are lacking. In this study, the influence model of calibration light sources on spectral calibration accuracy is established, and the spectral radiance acquired via GAS-2 is simulated using the line-by-line radiative transfer model (LBLRTM). We investigated the impact of different linewidths and wavelength stabilities of the calibration light source on its accuracy in four wavelength bands. This study is the first to examine the effects of the linewidth and wavelength stability of a calibration light source on the spectral radiance acquired via GAS-2. The initial results demonstrate that if the linewidth of the calibration light source is approximately 100 MHz and the wavelength stability is in the order of subpicometers, the radiance error obtained by GAS-2 is less than 10%. Among the four bands, the 2.06 μm (strong-CO2) band is more affected by the calibration light source than the other three bands. In addition, the wavelength stability of the light source has a greater influence on the error than the linewidth of the light source under the same error condition. The research findings can be used to guide and reference the selection of light sources in the laboratory spectral calibration of GAS-2, ultimately contributing to the instrument’s quantitative development level.

Funder

National Natural Science Foundation of China

Innovation Program, Shanghai Institute of Technical Physics, Chinese Academy of Sciences

Publisher

MDPI AG

Subject

General Earth and Planetary Sciences

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献