Abstract
The protection provided by wearing masks has been a guideline worldwide to prevent the risk of COVID-19 infection. The current work presents an investigation that analyzes the effectiveness of face shields as personal protective equipment. To that end, a multiphase computational fluid dynamic study based on Eulerian–Lagrangian techniques was defined to simulate the spread of the droplets produced by a sneeze. Different scenarios were evaluated where the relative humidity, ambient temperature, evaporation, mass transfer, break up, and turbulent dispersion were taken into account. The saliva that the human body generates was modeled as a saline solution of 8.8 g per 100 mL. In addition, the influence of the wind speed was studied with a soft breeze of 7 km/h and a moderate wind of 14 km/h. The results indicate that the face shield does not provide accurate protection, because only the person who is sneezed on is protected. Moreover, with a wind of 14 km/h, none of the droplets exhaled into the environment hit the face shield, instead, they were deposited onto the neck and face of the wearer. In the presence of an airflow, the droplets exhaled into the environment exceeded the safe distance marked by the WHO. Relative humidity and ambient temperature play an important role in the lifetime of the droplets.
Funder
Ekonomiaren Garapen eta Lehiakortasun Saila, Eusko Jaurlaritza
Subject
General Mathematics,Engineering (miscellaneous),Computer Science (miscellaneous)
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献