Acetabular Revision Surgery with Tantalum Trabecular Metal Acetabular Cup for Failed Acetabular Cage Reconstruction with Bone Allografts: A Retrospective Study with Mid- to Long-Term Follow-Up

Author:

Hsu Chen-Heng,Hu Chih-ChienORCID,Chang Chih-Hsiang,Chang Yu-Han,Shih Hsin-Nung,Chen Chun-Chieh

Abstract

Background: Acetabular cage reconstruction with bone allografts is among the successful strategies to deal with massive acetabular bone loss. However, the nonbiological fixation nature of cages can compromise long-term success. Tantalum trabecular metal acetabular cups (TM cups) have been used in acetabular revision surgery because of their increased initial stability and good bone ingrowth features. This study was performed to determine whether the bone stock of the acetabulum is enough to support a hemispheric TM cup after failed cage reconstruction with bone allografts. Methods: We retrospectively reviewed patients who received acetabular revision surgery with TM cups after failed cage reconstruction with bone allografts from 2006 to 2017. There were 12 patients (5 males and 7 females) included in this study, with a mean age of 61.5 years (38 to 81) at the time of re-revision surgery. The mean follow-up after re-revision surgery was 8.6 years (2.6 to 13.3). The endpoint was defined as the aseptic loosening of the TM cup and reoperation for any causes. The change in bone stock of the acetabulum between index revision and re-revision was assessed according to the Gross classification for acetabular bone loss. Results: One patient died after eight years of follow-up of a cause not related to hip surgery. Two patients received two-stage revision arthroplasty due to PJI after 3.2 and 9.4 years of follow-up, respectively. The bone stock of the acetabulum was significantly improved between index revision and re-revision surgery (p < 0.0001). The Kaplan–Meier survivorship was 100% with aseptic loosening as the endpoint and 90% and 75% at five- and ten-year follow-up, respectively, with reoperation for any reason as the endpoint. Even cage reconstruction with bone allografts will fail eventually, and the bone stock of the acetabulum will improve after union and incorporation between host bone and allografts. The restored bone stocks will facilitate further revision surgery with hemispheric TM cups. The biological fixation between host bone and tantalum trabecular metal can provide longstanding stability of the TM cup. Conclusions: The results of our study offer a viable option for patients with failed cage reconstruction with bone allografts.

Publisher

MDPI AG

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3