A Portable, Neurostimulation-Integrated, Force Measurement Platform for the Clinical Assessment of Plantarflexor Central Drive

Author:

Collimore Ashley N.1ORCID,Alvarez Jonathan T.2ORCID,Sherman David A.23ORCID,Gerez Lucas F.2ORCID,Barrow Noah1,Choe Dabin K.2,Binder-Macleod Stuart4ORCID,Walsh Conor J.2,Awad Louis N.1ORCID

Affiliation:

1. Department of Physical Therapy, Sargent College of Health and Rehabilitation Sciences, Boston University, Boston, MA 02215, USA

2. Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA

3. Section of Rheumatology, Boston University, Boston, MA 02215, USA

4. Department of Physical Therapy, University of Delaware, Newark, DE 19716, USA

Abstract

Plantarflexor central drive is a promising biomarker of neuromotor impairment; however, routine clinical assessment is hindered by the unavailability of force measurement systems with integrated neurostimulation capabilities. In this study, we evaluate the accuracy of a portable, neurostimulation-integrated, plantarflexor force measurement system we developed to facilitate the assessment of plantarflexor neuromotor function in clinical settings. Two experiments were conducted with the Central Drive System (CEDRS). To evaluate accuracy, experiment #1 included 16 neurotypical adults and used intra-class correlation (ICC2,1) to test agreement of plantarflexor strength capacity measured with CEDRS versus a stationary dynamometer. To evaluate validity, experiment #2 added 26 individuals with post-stroke hemiparesis and used one-way ANOVAs to test for between-limb differences in CEDRS’ measurements of plantarflexor neuromotor function, comparing neurotypical, non-paretic, and paretic limb measurements. The association between paretic plantarflexor neuromotor function and walking function outcomes derived from the six-minute walk test (6MWT) were also evaluated. CEDRS’ measurements of plantarflexor neuromotor function showed high agreement with measurements made by the stationary dynamometer (ICC = 0.83, p < 0.001). CEDRS’ measurements also showed the expected between-limb differences (p’s < 0.001) in maximum voluntary strength (Neurotypical: 76.21 ± 13.84 ft-lbs., Non-paretic: 56.93 ± 17.75 ft-lbs., and Paretic: 31.51 ± 14.08 ft-lbs.), strength capacity (Neurotypical: 76.47 ± 13.59 ft-lbs., Non-paretic: 64.08 ± 14.50 ft-lbs., and Paretic: 44.55 ± 14.23 ft-lbs.), and central drive (Neurotypical: 88.73 ± 1.71%, Non-paretic: 73.66% ± 17.74%, and Paretic: 52.04% ± 20.22%). CEDRS-measured plantarflexor central drive was moderately correlated with 6MWT total distance (r = 0.69, p < 0.001) and distance-induced changes in speed (r = 0.61, p = 0.002). CEDRS is a clinician-operated, portable, neurostimulation-integrated force measurement platform that produces accurate measurements of plantarflexor neuromotor function that are associated with post-stroke walking ability.

Funder

Boston University Ignition Award, the National Institutes of Health

National Institutes of Health (NIH) Blueprint for Neuroscience Research

National Institute of Child Health and Human Development

National Institute of Neurological Disorders and Stroke

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3