Abstract

The main aim of this study was to perform a complex biomechanical analysis for a custom-designed temporomandibular joint (TMJ) prosthesis in combination with a fibular free flap in a pediatric case. Numerical simulations in seven variants of loads were carried out on 3D models obtained based on CT images of a 15-year-old patient in whom it was necessary to reconstruct the temporal-mandibular joints with the use of a fibula autograft. The implant model was designed based on the patient’s geometry. Experimental tests on a manufactured personalized implant were carried out on the MTS Insight testing machine. Two methods of fixing the implant to the bone were analyzed—using three or five bone screws. The greatest stress was located on the top of the head of the prosthesis. The stress on the prosthesis with the five-screw configuration was lower than in the prosthesis with the three-screw configuration. The peak load analysis shows that the samples with the five-screw configuration have a lower deviation (10.88, 0.97, and 32.80%) than the groups with the three-screw configuration (57.89 and 41.10%). However, in the group with the five-screw configuration, the fixation stiffness was relatively lower (a higher value of peak load by displacement of 171.78 and 86.46 N/mm) than in the group with the three-screw configuration (where the peak load by displacement was 52.93, 60.06, and 78.92 N/mm). Based on the experimental and numerical studies performed, it could be stated that the screw configuration is crucial for biomechanical analysis. The results obtained may be an indication for surgeons, especially during planning personalized reconstruction procedures.

Funder

ChM Polska

Publisher

MDPI AG

Subject

Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3