Ultra-Low Intensity Post-Pulse Affects Cellular Responses Caused by Nanosecond Pulsed Electric Fields

Author:

Asadipour Kamal12ORCID,Zhou Carol2,Yi Vincent3,Beebe Stephen J.2ORCID,Xiao Shu12

Affiliation:

1. Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, VA 23529, USA

2. Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA 23529, USA

3. Ocean Lakes High School, Virginia Beach, VA 23454, USA

Abstract

High-intensity nanosecond pulse electric fields (nsPEF) can preferentially induce various effects, most notably regulated cell death and tumor elimination. These effects have almost exclusively been shown to be associated with nsPEF waveforms defined by pulse duration, rise time, amplitude (electric field), and pulse number. Other factors, such as low-intensity post-pulse waveform, have been completely overlooked. In this study, we show that post-pulse waveforms can alter the cell responses produced by the primary pulse waveform and can even elicit unique cellular responses, despite the primary pulse waveform being nearly identical. We employed two commonly used pulse generator designs, namely the Blumlein line (BL) and the pulse forming line (PFL), both featuring nearly identical 100 ns pulse durations, to investigate various cellular effects. Although the primary pulse waveforms were nearly identical in electric field and frequency distribution, the post-pulses differed between the two designs. The BL’s post-pulse was relatively long-lasting (~50 µs) and had an opposite polarity to the main pulse, whereas the PFL’s post-pulse was much shorter (~2 µs) and had the same polarity as the main pulse. Both post-pulse amplitudes were less than 5% of the main pulse, but the different post-pulses caused distinctly different cellular responses. The thresholds for dissipation of the mitochondrial membrane potential, loss of viability, and increase in plasma membrane PI permeability all occurred at lower pulsing numbers for the PFL than the BL, while mitochondrial reactive oxygen species generation occurred at similar pulsing numbers for both pulser designs. The PFL decreased spare respiratory capacity (SRC), whereas the BL increased SRC. Only the PFL caused a biphasic effect on trans-plasma membrane electron transport (tPMET). These studies demonstrate, for the first time, that conditions resulting from low post-pulse intensity charging have a significant impact on cell responses and should be considered when comparing the results from similar pulse waveforms.

Funder

UUS AFOSR

Publisher

MDPI AG

Subject

Bioengineering

Reference54 articles.

1. Beebe, S.J., Joshi, R., Schoenbach, K.H., and Xiao, S. (2021). Ultrashort Electric Pulse Effects in Biology and Medicine, Springer.

2. Review of Developments in Bioelectrics as an Application of Pulsed Power Technology;Joshi;IEEE Trans. Plasma Sci.,2023

3. Cell death due to electroporation—A review;Bioelectrochemistry,2021

4. Long-lasting plasma membrane permeabilization in mammalian cells by nanosecond pulsed electric field (nsPEF);Pakhomov;Bioelectromagn. J. Bioelectromagn. Soc. Soc. Phys. Regul. Biol. Med. Eur. Bioelectromagn. Assoc.,2007

5. Nanosecond Pulsed Electric Fields: A New Stimulus to Activate Intracellular Signaling;Beebe;J. Biomed. Biotechnol.,2005

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3