Affiliation:
1. Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, VA 23529, USA
2. Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA 23529, USA
3. Ocean Lakes High School, Virginia Beach, VA 23454, USA
Abstract
High-intensity nanosecond pulse electric fields (nsPEF) can preferentially induce various effects, most notably regulated cell death and tumor elimination. These effects have almost exclusively been shown to be associated with nsPEF waveforms defined by pulse duration, rise time, amplitude (electric field), and pulse number. Other factors, such as low-intensity post-pulse waveform, have been completely overlooked. In this study, we show that post-pulse waveforms can alter the cell responses produced by the primary pulse waveform and can even elicit unique cellular responses, despite the primary pulse waveform being nearly identical. We employed two commonly used pulse generator designs, namely the Blumlein line (BL) and the pulse forming line (PFL), both featuring nearly identical 100 ns pulse durations, to investigate various cellular effects. Although the primary pulse waveforms were nearly identical in electric field and frequency distribution, the post-pulses differed between the two designs. The BL’s post-pulse was relatively long-lasting (~50 µs) and had an opposite polarity to the main pulse, whereas the PFL’s post-pulse was much shorter (~2 µs) and had the same polarity as the main pulse. Both post-pulse amplitudes were less than 5% of the main pulse, but the different post-pulses caused distinctly different cellular responses. The thresholds for dissipation of the mitochondrial membrane potential, loss of viability, and increase in plasma membrane PI permeability all occurred at lower pulsing numbers for the PFL than the BL, while mitochondrial reactive oxygen species generation occurred at similar pulsing numbers for both pulser designs. The PFL decreased spare respiratory capacity (SRC), whereas the BL increased SRC. Only the PFL caused a biphasic effect on trans-plasma membrane electron transport (tPMET). These studies demonstrate, for the first time, that conditions resulting from low post-pulse intensity charging have a significant impact on cell responses and should be considered when comparing the results from similar pulse waveforms.
Reference54 articles.
1. Beebe, S.J., Joshi, R., Schoenbach, K.H., and Xiao, S. (2021). Ultrashort Electric Pulse Effects in Biology and Medicine, Springer.
2. Review of Developments in Bioelectrics as an Application of Pulsed Power Technology;Joshi;IEEE Trans. Plasma Sci.,2023
3. Cell death due to electroporation—A review;Bioelectrochemistry,2021
4. Long-lasting plasma membrane permeabilization in mammalian cells by nanosecond pulsed electric field (nsPEF);Pakhomov;Bioelectromagn. J. Bioelectromagn. Soc. Soc. Phys. Regul. Biol. Med. Eur. Bioelectromagn. Assoc.,2007
5. Nanosecond Pulsed Electric Fields: A New Stimulus to Activate Intracellular Signaling;Beebe;J. Biomed. Biotechnol.,2005
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献