Selection of Bifurcated Grafts’ Dimensions during Aorto-Iliac Vascular Reconstruction Based on Their Hemodynamic Performance

Author:

Tzirakis Konstantinos1ORCID,Kamarianakis Yiannis2ORCID,Kontopodis Nikolaos3,Ioannou Christos V.3ORCID

Affiliation:

1. Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Crete, Greece

2. Data Science Group, Institute of Applied and Computational Mathematics, Foundation for Research and Technology-Hellas, 70013 Heraklion, Crete, Greece

3. Vascular Surgery Department, Medical School, University of Crete, 71003 Heraklion, Crete, Greece

Abstract

During the vascular surgical reconstruction of aorto-iliac occlusive/aneurysmal disease, bifurcated grafts are used where vascular surgeons intra-operatively select the size and the relative lengths of the parent and daughter portions of the graft. Currently, clinical practice regarding the selection of the most favorable geometric configuration of the graft is an understudied research subject: decisions are solely based on the clinical experience of the operating surgeon. This manuscript aims to evaluate the hemodynamic performance of various diameters, D, of bifurcated aortic grafts and relate those with proximal/distal part length ratios (the angle φ between the limbs is used as a surrogate marker of the main body-to-limb length ratio) in order to provide insights regarding the effects of different geometries on the hemodynamic environment. To this end, a computationally intensive set of simulations is conducted, and the resulting data are analyzed with modern statistical regression tools. A negative curvilinear relationship of TAWSS with both φ and D is recorded. It is shown that the angle between limbs is a more important predictor for the variability of TAWSS, while the graft’s diameter is an important determinant for the variability of OSI. Large percentages of the total graft area with TAWSS < 0.4 Pa, which correspond to thrombogenic stimulating environments, are only observed for large values of φ and D > 20 mm. This variable ranges from 10% (for the smallest values of φ and D) to 55% (for the largest φ and D values). Our findings suggest that grafts with the smallest possible angle between the limbs (i.e., smallest parent-to-daughter length ratio) present the most favorable hemodynamic performance, yielding the smallest percentage of total graft area under thrombogenic simulating environments. Similarly, grafts with the smallest acceptable diameter should be preferred for the same reason. Especially, grafts with diameters greater than 20 mm should be avoided, given the abrupt increase in estimated thrombogenic areas.

Publisher

MDPI AG

Subject

Bioengineering

Reference41 articles.

1. Editor’s Choice-European Society for Vascular Surgery (ESVS) 2019 Clinical Practice Guidelines on the Management of Abdominal Aorto-iliac Artery Aneurysms;Wanhainen;Eur. J. Vasc. Endovasc. Surg.,2019

2. Global Vascular Guidelines on the Management of Chronic Limb-Threatening Ischemia;Conte;Eur. J. Vasc. Endovasc. Surg.,2019

3. on behalf of the TASC II Working Group. Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II);Norgren;J. Vasc. Surg.,2007

4. Computational estimation of the influence of the main body-to-iliac limb length ratio on the displacement forces acting on an aortic endograft. Theoretical application to Bolton Treovance® Abdominal Stent-Graft;Georgakarakos;Int. Angiol.,2014

5. Estimating the hemodynamic influence of variable main body-to-iliac limb length ratios in aortic endografts;Georgakarakos;Int. Angiol.,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3