Using Contactless Facial Image Recognition Technology to Detect Blood Oxygen Saturation

Author:

Cheng Jui-Chuan1,Pan Tzung-Shiarn1,Hsiao Wei-Cheng2,Lin Wei-Hong1,Liu Yan-Liang1,Su Te-Jen13ORCID,Wang Shih-Ming4

Affiliation:

1. Department of Electronic Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 80782, Taiwan

2. Division of Gastroenterology (General Medicine), Department of Internal Medicine, Yuan’s General Hospital, No. 162, Cheng Kung 1st Rd., Lingya District, Kaohsiung 80249, Taiwan

3. Department of Telecommunication Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 80782, Taiwan

4. Department of Computer Science and Information Engineering, Cheng Shiu University, Kaohsiung 833, Taiwan

Abstract

Since the outbreak of COVID-19, as of January 2023, there have been over 670 million cases and more than 6.8 million deaths worldwide. Infections can cause inflammation in the lungs and decrease blood oxygen levels, which can lead to breathing difficulties and endanger life. As the situation continues to escalate, non-contact machines are used to assist patients at home to monitor their blood oxygen levels without encountering others. This paper uses a general network camera to capture the forehead area of a person’s face, using the RPPG (remote photoplethysmography) principle. Then, image signal processing of red and blue light waves is carried out. By utilizing the principle of light reflection, the standard deviation and mean are calculated, and the blood oxygen saturation is computed. Finally, the effect of illuminance on the experimental values is discussed. The experimental results of this paper were compared with a blood oxygen meter certified by the Ministry of Health and Welfare in Taiwan, and the experimental results had only a maximum error of 2%, which is better than the 3% to 5% error rates in other studies The measurement time was only 30 s, which is better than the one minute reported using similar equipment in other studies. Therefore, this paper not only saves equipment expenses but also provides convenience and safety for those who need to monitor their blood oxygen levels at home. Future applications can combine the SpO2 detection software with camera-equipped devices such as smartphones and laptops. The public can detect SpO2 on their own mobile devices, providing a convenient and effective tool for personal health management.

Publisher

MDPI AG

Subject

Bioengineering

Reference30 articles.

1. Noncontact SpO2 Measurement Using Eulerian Video Magnification;Rosa;IEEE Trans. Instrum. Meas.,2022

2. Torres, J.C., and Abderrahim, M. (2017, January 5–7). Simple measurement of pulse oximetry using a standard color camera. Proceedings of the 2017 40th International Conference on Telecommunications and Signal Processing (TSP), Barcelona, Spain.

3. Non-contact remote estimation of cardiovascular parameter;Fan;Biomed. Signal Process. Control.,2018

4. A noncontact skin oxygen-saturation imaging system for measuring human tissue oxygen saturation;Tsai;IEEE Trans. Instrum. Meas.,2014

5. Non-contact detection of oxygen saturation based on visible light imaging device using ambient light;Kong;Opt. Express,2013

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3