Rapid Morphological Measurement Method of Aortic Dissection Stent Based on Spatial Observation Point Set

Author:

Bai Mateng,Li Da,Xu Kaiyao,Ouyang Shuyu,Yuan Ding,Zheng TinghuiORCID

Abstract

Objectives: Post-operative stent morphology of aortic dissection patients is important for performing clinical diagnosis and prognostic assessment. However, stent morphologies still need to be manually measured, which is a process prone to errors, high time consumption and difficulty in exploiting inter-data associations. Herein, we propose a method based on the stepwise combination of basic, non-divisible data sets to quickly obtain morphological parameters with high accuracy. Methods: We performed the 3D reconstruction of 109 post-operative follow-up CT image data from 26 patients using mimics software. By extracting the spatial locations of the basic morphological observation points on the stent, we defined a basic and non-reducible set of observation points. Further, we implemented a fully automatic stent segmentation and an observation point extraction algorithm. We analyzed the stability and accuracy of the algorithms on a test set containing 8 cases and 408 points. Based on this dataset, we calculated three morphological parameters of different complexity for the different spatial structural features exhibited by the stent. Finally, we compared the two measurement schemes in four aspects: data variability, data stability, statistical process complexity and algorithmic error. Results: The statistical results of the two methods on two low-complexity morphological parameters (spatial position of stent end and vascular stent end-slip volume) show good agreement (n = 26, P1, P2 < 0.001, r1 = 0.992, r2 = 0.988). The statistics of the proposed method for the morphological parameters of medium complexity (proximal support ring feature diameter and distal support ring feature diameter) avoid the errors caused by manual extraction, and the magnitude of this correction to the traditional method does not exceed 4 mm with an average correction of 1.38 mm. Meanwhile, our proposed automatic observation point extraction method has only 2.2% error rate on the test set, and the average spatial distance from the manually marked observation points is 0.73 mm. Thus, the proposed method is able to rapidly and accurately measure the stent circumferential deflection angle, which is highly complex and cannot be measured using traditional methods. Conclusions: The proposed method can significantly reduce the statistical observation time and information processing cost compared to the traditional morphological observation methods. Moreover, when new morphological parameters are required, one can quickly and accurately obtain the target parameters by new “combinatorial functions.” Iterative modification of the data set itself is avoided.

Funder

National Natural Science Foundation of China

Sichuan Science and Technology Department Support plan

Publisher

MDPI AG

Subject

Bioengineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3