Machine Learning-Based Respiration Rate and Blood Oxygen Saturation Estimation Using Photoplethysmogram Signals

Author:

Shuzan Md Nazmul Islam1ORCID,Chowdhury Moajjem Hossain1,Chowdhury Muhammad E. H.2ORCID,Murugappan Murugappan345ORCID,Hoque Bhuiyan Enamul6ORCID,Arslane Ayari Mohamed7ORCID,Khandakar Amith2ORCID

Affiliation:

1. Department of Electrical, Electronic and System Engineering, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia

2. Department of Electrical Engineering, Qatar University, Doha 2713, Qatar

3. Intelligent Signal Processing (ISP) Research Lab, Department of Electronics and Communication Engineering, Kuwait College of Science and Technology, Block 4, Doha 13133, Kuwait

4. Department of Electronics and Communication Engineering, School of Engineering, Vels Institute of Sciences, Technology and Advanced Studies, Chennai 600117, Tamil Nadu, India

5. Center for Excellence for Unmanned Aerial Systems, Universiti Malaysia Perlis, Perlis 02600, Malaysia

6. BioMedical Engineering and Imaging Institute (BMEII), Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA

7. Department of Civil and Architectural Engineering, Qatar University, Doha 2713, Qatar

Abstract

The continuous monitoring of respiratory rate (RR) and oxygen saturation (SpO2) is crucial for patients with cardiac, pulmonary, and surgical conditions. RR and SpO2 are used to assess the effectiveness of lung medications and ventilator support. In recent studies, the use of a photoplethysmogram (PPG) has been recommended for evaluating RR and SpO2. This research presents a novel method of estimating RR and SpO2 using machine learning models that incorporate PPG signal features. A number of established methods are used to extract meaningful features from PPG. A feature selection approach was used to reduce the computational complexity and the possibility of overfitting. There were 19 models trained for both RR and SpO2 separately, from which the most appropriate regression model was selected. The Gaussian process regression model outperformed all the other models for both RR and SpO2 estimation. The mean absolute error (MAE) for RR was 0.89, while the root-mean-squared error (RMSE) was 1.41. For SpO2, the model had an RMSE of 0.98 and an MAE of 0.57. The proposed system is a state-of-the-art approach for estimating RR and SpO2 reliably from PPG. If RR and SpO2 can be consistently and effectively derived from the PPG signal, patients can monitor their RR and SpO2 at a cheaper cost and with less hassle.

Funder

Qatar University Emergency Response

Publisher

MDPI AG

Subject

Bioengineering

Reference39 articles.

1. (2021, August 22). WHO Coronavirus (COVID-19) Dashboard|WHO Coronavirus (COVID-19) Dashboard with Vaccination Data. Available online: https://covid19.who.int/.

2. (2021, August 22). Vital Signs. Available online: https://my.clevelandclinic.org/health/articles/10881-vital-signs.

3. Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review;Charlton;IEEE Rev. Biomed. Eng.,2018

4. An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram;Charlton;Physiol. Meas.,2016

5. Extraction of respiratory signals from the electrocardiogram and photoplethysmogram: Technical and physiological determinants;Charlton;Physiol. Meas.,2017

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3