The Variation of Electrical Pulse Duration Elicits Reliable Network-Mediated Responses of Retinal Ganglion Cells in Normal, Not in Degenerate Primate Retinas

Author:

Cha Seongkwang1ORCID,Ahn Jungryul1,Kim Seong-Woo2,Choi Kwang-Eon3ORCID,Yoo Yongseok4,Eom Heejong5ORCID,Shin Donggwan5,Goo Yong Sook1ORCID

Affiliation:

1. Department of Physiology, College of Medicine, Chungbuk National University, Cheongju 28644, Republic of Korea

2. Horang-I Eye Center, Seoul 07999, Republic of Korea

3. Department of Ophthalmology, College of Medicine, Korea University, Seoul 08308, Republic of Korea

4. School of Computer Science and Engineering, Soongsil University, Seoul 06978, Republic of Korea

5. Laboratory Animal Center, Osong Medical Innovation Foundation, Cheongju 28160, Republic of Korea

Abstract

This study aims to investigate the efficacy of electrical stimulation by comparing network-mediated RGC responses in normal and degenerate retinas using a N-methyl-N-nitrosourea (MNU)-induced non-human primate (NHPs) retinitis pigmentosa (RP) model. Adult cynomolgus monkeys were used for normal and outer retinal degeneration (RD) induced by MNU. The network-mediated RGC responses were recorded from the peripheral retina mounted on an 8 × 8 multielectrode array (MEA). The amplitude and duration of biphasic current pulses were modulated from 1 to 50 μA and 500 to 4000 μs, respectively. The threshold charge density for eliciting a network-mediated RGC response was higher in the RD monkeys than in the normal monkeys (1.47 ± 0.13 mC/cm2 vs. 1.06 ± 0.09 mC/cm2, p < 0.05) at a 500 μs pulse duration. The monkeys required a higher charge density than rodents among the RD models (monkeys; 1.47 ± 0.13 mC/cm2, mouse; 1.04 ± 0.09 mC/cm2, and rat; 1.16 ± 0.16 mC/cm2, p < 0.01). Increasing the pulse amplitude and pulse duration elicited more RGC spikes in the normal primate retinas. However, only pulse amplitude variation elicited more RGC spikes in degenerate primate retinas. Therefore, the pulse strategy for primate RD retinas should be optimized, eventually contributing to retinal prosthetics. Given that RD NHP RGCs are not sensitive to pulse duration, using shorter pulses may potentially be a more charge-effective approach for retinal prosthetics.

Funder

National Research Foundation (NRF) of the Ministry of Science

Publisher

MDPI AG

Subject

Bioengineering

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3