The Development of a Permanent Implantable Spacer with the Function of Size Adjustability for Customized Treatment of Regurgitant Heart Valve Disease

Author:

Chon Min-Ku1ORCID,Jung Su-Jin2ORCID,Seo Jae-Young2ORCID,Shin Dong-Hoon3,Park Jun-Hui4,Kim Hyun-Sook5,Hahn Joo-Yong6,Kim Eun-Kyoung6,Lee Seung-Whan7,Park Yong-Hyun1,Lee Sang-Hyun1,Kim June-Hong1ORCID

Affiliation:

1. Department of Cardiology, School of Medicine, Pusan National University, Cardiovascular Center, Yangsan Hospital, Yangsan 50612, Republic of Korea

2. Department of Research Strategy Team, R&D Center, TAU MEDICAL Inc., Yangsan 50612, Republic of Korea

3. Department of Pathology, School of Medicine, Yangsan Hospital, Pusan National University, Yangsan 50612, Republic of Korea

4. Major of Human Bioconvergence, Division of Smart Healthcare, Pukyong National University, Busan 48513, Republic of Korea

5. Division of Cardiology, Department of Internal Medicine, Hallym University Sacred Heart Hospital, Anyang 14068, Republic of Korea

6. Division of Cardiology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea

7. Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea

Abstract

The Pivot Mandu is an innovative device featuring a leak-tight adjustable 3D balloon spacer, incorporating inner mesh support, an outer e-PTFE layer, and a compliant balloon in the middle layer with a specialized detachable system. To assess its feasibility, proof of concept was rigorously evaluated through bench testing and survival porcine animal experiments. The results demonstrated successful remote inflation of the balloon system, with the balloon spacer exhibiting sustained patent and functional integrity over an extended observation period of up to 6 months. A noteworthy feature of the newly designed 3D balloon spacer is its capability for easy size adjustment during procedures, enhancing its adaptability and practicality in clinical settings. This three-layered 3D balloon spacer, with its established long-term patency, exhibits highly encouraging outcomes that hold promise in overcoming the current limitations of spacer devices for heart valve diseases. Given the compelling results from preclinical investigations, the translation of the Pivot Mandu into human trials is strongly warranted.

Funder

Kora government

Publisher

MDPI AG

Subject

Bioengineering

Reference22 articles.

1. Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: A propensity score analysis;Thourani;Lancet,2016

2. Mitral loop cerclage as a variant form of mitral cerclage annuloplasty that adds a device (CSTV) for preventing potential complications: A preclinical proof of concept and feasibility study;Kim;Eurointerv. J. Eur. Collab. Work. Group Interv. Cardiol. Eur. Soc. Cardiol.,2016

3. Transcatheter tricuspid valve interventions: Landscape, challenges, and future directions;Asmarats;J. Am. Coll. Cardiol.,2018

4. Long-term outcomes of the FORMA transcatheter tricuspid valve repair system for the treatment of severe tricuspid regurgitation: Insights from the first-in-human experience;Asmarats;JACC Cardiovasc. Interv.,2019

5. Preclinical in vivo long-term evaluation of the novel Mitra-Spacer technology: Experimental validation in the ovine model;Peppas;Eurointerv. J. Eur. Collab. Work. Group Interv. Cardiol. Eur. Soc. Cardiol.,2017