Multilesion Segmentations in Patients with Intracerebral Hemorrhage: Reliability of ICH, IVH and PHE Masks

Author:

Vogt Estelle,Vu Ly Huong,Cao Haoyin,Speth Anna,Desser Dmitriy,Schlunk Frieder,Dell’Orco AndreaORCID,Nawabi JawedORCID

Abstract

Background and Purpose: Fully automated methods for segmentation and volume quantification of intraparenchymal hemorrhage (ICH), intraventricular hemorrhage extension (IVH), and perihematomal edema (PHE) are gaining increasing interest. Yet, reliabilities demonstrate considerable variances amongst each other. Our aim was therefore to evaluate both the intra- and interrater reliability of ICH, IVH and PHE on ground-truth segmentation masks. Methods: Patients with primary spontaneous ICH were retrospectively included from a German tertiary stroke center (Charité Berlin; January 2016–June 2020). Baseline and follow-up non-contrast Computed Tomography (NCCT) scans were analyzed for ICH, IVH, and PHE volume quantification by two radiology residents. Raters were blinded to all demographic and outcome data. Inter- and intrarater agreements were determined by calculating the Intraclass Correlation Coefficient (ICC) for a randomly selected set of patients with ICH, IVH, and PHE. Results: 100 out of 670 patients were included in the analysis. Interrater agreements ranged from an ICC of 0.998 for ICH (95% CI [0.993; 0.997]), to an ICC of 0.979 for IVH (95% CI [0.984; 0.993]), and an ICC of 0.886 for PHE (95% CI [0.760; 0.938]), all p-values < 0.001. Intrarater agreements ranged from an ICC of 0.997 for ICH (95% CI [0.996; 0.998]), to an ICC of 0.995 for IVH (95% CI [0.992; 0.996]), and an ICC of 0.980 for PHE (95% CI [0.971; 0.987]), all p-values < 0.001. Conclusion Manual segmentations of ICH, IVH, and PHE demonstrate good-to-excellent inter- and intrarater reliabilities, with the highest agreement for ICH and IVH and lowest for PHE. Therefore, the degree of variances reported in fully automated quantification methods might be related amongst others to variances in ground-truth masks.

Publisher

MDPI AG

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3