Comparing Radiation Dose of Cerebral Angiography Using Conventional and High kV Techniques: A Retrospective Study on Intracranial Aneurysm Patients and a Phantom Study

Author:

Kirisattayakul Woranan1ORCID,Pattum Panuwat1,Munkong Waranon1,Prabsattroo Thawatchai1ORCID,Khottapat Chonnatcha1,Chomkhunthod Tanyalak1,Pungkun Vithit2

Affiliation:

1. Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand

2. Office of Atoms for Peace, Ministry of Higher Education, Science, Research and Innovation, Bangkok 10900, Thailand

Abstract

Evaluation of patient radiation dose after the implementation of a high kV technique during a cerebral angiographic procedure is an important issue. This study aimed to determine and compare the patient radiation dose of intracranial aneurysm patients undergoing cerebral angiography using the conventional and high kV techniques in a retrospective study and a phantom study. A total of 122 cases (61 cases with conventional technique and 61 cases with high kV technique) of intracranial aneurysm patients, who underwent cerebral angiographic procedure and met the inclusion criteria, were recruited. The radiation dose and the angiographic exposure parameters were reviewed retrospectively. The radiation dose in the phantom study was conducted using nanoDotTM optically stimulating luminescence (OSLD), which were placed on the scalp of the head phantom, the back of the neck, and the phantom skin at the position of the eyes. The standard cerebral angiographic procedure using the conventional and high kV techniques was performed following the standard protocol. The results showed that the high kV technique significantly reduced patient radiation dose and phantom skin dose. This study confirms that the implementation of a high kV technique in routine cerebral angiography for aneurysm diagnosis provides an effective reduction in radiation dose. Further investigation of radiation dose in other interventional neuroradiology procedures, particularly embolization procedure, should be performed.

Funder

Research and Graduate Studies, Khon Kaen University

Publisher

MDPI AG

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3