Updated National Diagnostic Reference Levels and Achievable Doses for CT Protocols: A National Survey of Korean Hospitals

Author:

Nam SoraORCID,Park HyeminORCID,Kwon Soonmu,Cho Pyong-kon,Yoon YongsuORCID,Yoon Sang-wook,Kim JungsuORCID

Abstract

Background: In 2021, the Korean government proposed a new CT diagnostic reference level. This study performed a nationwide survey and developed new DRLs and AD for 13 common CT examinations. We compared other countries’ DRLs for CT examinations. Methods: This study investigated the CTDIvol and DLP of the 12 types of CT protocols for adults and brain CT protocol for pediatrics. A total of 7829 CT examinations were performed using 225 scanners. We defined the DRLs values in the distribution of radiation exposure levels to determine the nationwide patient dose and distribution status of the dose. Results: This study showed that the new Korean national CT DRLs are slightly higher or similar to those of previous surveys and are similar or lower than those of other countries. In some protocols, although the DLP value increased, the CTDIvol decreased; therefore, it can be concluded that the patient’s dose in CT examinations was well managed. Conclusions: The new CT DRLs were slightly higher than or similar to that of the previous survey and were evaluated to be similar or lower than CT DRLs of other countries. These DRLs will be used for radiation optimization and effective dose calculation for an individual.

Funder

Korea Disease Control and Prevention Agency

Publisher

MDPI AG

Subject

Radiology, Nuclear Medicine and imaging

Reference23 articles.

1. Computerized transverse axial scanning (tomography): Part 1. Description of system

2. Computed tomography scanning with simultaneous patient translation

3. Performance evaluation of a multi-slice CT system

4. Patient Exposure from Radiologic and Nuclear Medicine Procedures in the United States: Procedure Volume and Effective Dose for the Period 2006–2016

5. IAEA Safety Series No. 115/CD, International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (CD-ROM Edition, 2003), International Atomic Energy Agency (2003) https://www.iaea.org/publications/6900/international-basic-safety-standards-for-protection-against-ionizing-radiation-and-for-the-safety-of-radiation-sources-cd-rom-edition-2003

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献