Electrocardiographic Characteristics of Ventricular Arrhythmias Originating from Different Areas Adjacent to the Mitral Annulus

Author:

Lin Yi-Fan12ORCID,Xu Que1,Zheng Cheng1,Shao Jia-Meng1,Shen Bing1,He Rui-Lin1,Lin Jia-Feng1,Chen Yan-Ru1

Affiliation:

1. Department of Cardiology, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou 325000, China

2. Department of Cardiology, The Third Affiliated Hospital of Wenzhou Medical University and Ruian People’s Hospital, Wenzhou 325000, China

Abstract

Background: This study aimed to explore the electrocardiographic (ECG) characteristics of ventricular arrhythmias (VAs) arising from epicardial and endocardial areas adjacent to the mitral annulus (MA). Methods: This study involved 283 patients with MA-VAs who received radiofrequency catheter ablation at the center. The ECG characteristics of these patients were analyzed retrospectively. Results: The origin of MA-VAs was judged based on the ECG variables. Among all MA-VAs, intrinsicoid deflection time (IDT) > 77 ms or maximum deflection index (MDI) > 0.505 predicted the VAs arising from the epicardium (sensitivity of 70.20% and 73.51%, specificity of 94.70% and 82.58%, positive predictive value (PPV) of 93.81% and 82.84%, and negative predictive value (NPV) of 73.53% and 73.15%). Among all epicardial MA-VAs, the RV1/RV2 ratio > 0.87 predicted the VAs originating from the epicardial anteroseptal wall adjacent to the MA. It had a sensitivity, specificity, PPV, and NPV of 62.86%, 98.06%, 91.67%, and 88.60%, respectively. Among all endocardial MA-VAs, Q(q)R(r) morphology in lead V1 predicted the VAs arising from the endocardial septal wall adjacent to the MA. It had a sensitivity, specificity, PPV, and NPV of 92.98%, 100%, 100%, and 94.94%, respectively. Among all endocardial septal MA-VAs, a predominant positive wave in lead II and a predominant negative wave in lead III predicted the VAs arising from the endocardial midseptal portion adjacent to the MA. It had a sensitivity, specificity, PPV, and NPV of 86.04%, 100%, 100%, and 70.00%, respectively. Conclusion: the ECG characteristics of VAs from the different sites adjacent to the MA can enable judging the arrhythmia’s origin and designing the ablation plan accordingly.

Funder

Wenzhou Municipal Science and Technology Commission

Zhejiang Provincial Natural Science Foundation

National Natural Science Foundation of China

Publisher

MDPI AG

Subject

Pharmacology (medical),General Pharmacology, Toxicology and Pharmaceutics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3