Towards an Intrinsic Doppler Correction for X-ray Spectroscopy of Stored Ions at CRYRING@ESR

Author:

Kröger Felix Martin123ORCID,Weber Günter23ORCID,Allgeier Steffen4,Andelkovic Zoran3,Bernitt Sonja123ORCID,Borovik Alexander5,Duval Louis6ORCID,Fleischmann Andreas4,Forstner Oliver123ORCID,Friedrich Marvin4,Glorius Jan3,Gumberidze Alexandre3ORCID,Hahn Christoph23ORCID,Herfurth Frank3,Hengstler Daniel4,Herdrich Marc Oliver123ORCID,Hillenbrand Pierre-Michel35ORCID,Kalinin Anton3,Kiffer Markus123,Kubullek Maximilian1,Kuntz Patricia4,Lestinsky Michael3ORCID,Löher Bastian3ORCID,Menz Esther Babette123ORCID,Over Tobias12ORCID,Petridis Nikolaos3ORCID,Pfäfflein Philip123ORCID,Ringleb Stefan123,Sidhu Ragandeep Singh3ORCID,Spillmann Uwe3ORCID,Trotsenko Sergiy23,Warczak Andrzej7,Zhu Binghui123ORCID,Enss Christian4,Stöhlker Thomas123ORCID

Affiliation:

1. Institute of Optics and Quantum Electronics, Friedrich Schiller University Jena, 07743 Jena, Germany

2. Helmholtz Institute Jena, 07743 Jena, Germany

3. GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt, Germany

4. Kirchhoff Institute for Physics, Heidelberg University, 69120 Heidelberg, Germany

5. I. Physikalisches Institut, Justus-Liebig-Universität Gießen, 35392 Gießen, Germany

6. Laboratoire Kastler Brossel, Sorbonne Université, 75005 Paris, France

7. Marian Smoluchowski Institute of Physics, Jagiellonian University, 30-348 Kraków, Poland

Abstract

We report on a new experimental approach for the Doppler correction of X-rays emitted by heavy ions, using novel metallic magnetic calorimeter detectors which uniquely combine a high spectral resolution with a broad bandwidth acceptance. The measurement was carried out at the electron cooler of CRYRING@ESR at GSI, Darmstadt, Germany. The X-ray emission associated with the radiative recombination of cooler electrons and stored hydrogen-like uranium ions was investigated using two novel microcalorimeter detectors positioned under 0∘ and 180∘ with respect to the ion beam axis. This new experimental setup allowed the investigation of the region of the N, M → L transitions in helium-like uranium with a spectral resolution unmatched by previous studies using conventional semiconductor X-ray detectors. When assuming that the rest-frame energy of at least a few of the recorded transitions is well-known from theory or experiments, a precise measurement of the Doppler shifted line positions in the laboratory system can be used to determine the ion beam velocity using only spectral information. The spectral resolution achievable with microcalorimeter detectors should, for the first time, allow intrinsic Doppler correction to be performed for the precision X-ray spectroscopy of stored heavy ions. A comparison with data from a previous experiment at the ESR electron cooler, as well as the conventional method of conducting Doppler correction using electron cooler parameters, will be discussed.

Funder

European Research Council

Verbundprojekt BMBF

ErUM FSP T05—“Aufbau von APPA bei FAIR”

Publisher

MDPI AG

Subject

Condensed Matter Physics,Nuclear and High Energy Physics,Atomic and Molecular Physics, and Optics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司