Advancing Urban Wastewater Management: Optimizing Sewer Performance through Innovative Material Selection for the Armlet with a Wet Circuit Measurement System

Author:

Sionkowski Tomasz1,Halecki Wiktor2ORCID,Chmielowski Krzysztof3

Affiliation:

1. Grundfos Pompy Ltd., Klonowa Street 23, 62-081 Przeźmierowo, Poland

2. Institute of Nature Conservation Polish Academy of Sciences, Mickiewicza 33, 31-120 Krakow, Poland

3. Department of Natural Gas Engineering, Faculty of Drilling, Oil and Gas, AGH University of Science and Technology, Al. A. Mickiewicza 30, 30-059 Krakow, Poland

Abstract

Rainwater infiltration presents substantial challenges for urban wastewater management systems. This article delves into enhancing the quality of wastewater systems by proposing a novel device designed to tackle this issue comprehensively. The focal point of our research revolves around the conceptualization, construction, rigorous testing, and the potential multifaceted applications of this innovative wastewater device. Our study is dedicated to assessing the viability of a cutting-edge apparatus that empowers municipal entities in swiftly identifying rainwater ingress points within channels during precipitation events. Our findings vividly showcase the device’s remarkable capability to directly measure moisture levels along the channel’s path, eliminating the arduous need for manual data input, extensive data collection, and intricate water analysis procedures. To ensure the seamless flow of both sewage and water within the sewer channel, the use of a relatively slender strap is conventionally favored. However, factoring in the requisite structural robustness, we recommend a minimum thickness of 4 mm for 3D printing applications. For instances where maintaining the channel’s cross-sectional area integrity is paramount, opting for an armlet with a wet circuit measurement thickness of up to 7 mm is vital. In the realm of material selection, our investigation advocates for the utilization of PC/ABS (polycarbonate/Acrylonitrile Butadiene Styrene), ABS, ASA (Acrylonitrile Styrene Acrylate), or HIPS (High Impact Polystyrene) for strap housing. For sewer diameters surpassing 315 mm, the application of thin-walled PVC (Poly Vinyl Chloride) emerges as a practical recommendation. Notably, the incorporation of PVC flat bars is discouraged, as their presence might potentially hinder the fluidity of sewage flow, thereby compromising the precision of wet circuit measurements. The pivotal innovation lies in the armlet with a wet circuit measurement system, harboring immense potential for broad-scale integration across municipal facilities. This solution emerges as a streamlined and efficient strategy, offering a comprehensive avenue for continuously monitoring, fine-tuning, and optimizing the structural soundness and operational efficacy of sewer systems.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3