Experimental Study on the Active Control and Dynamic Characteristics of Electromagnetic Active–Passive Hybrid Vibration Isolation System
-
Published:2023-09-22
Issue:19
Volume:13
Page:10565
-
ISSN:2076-3417
-
Container-title:Applied Sciences
-
language:en
-
Short-container-title:Applied Sciences
Author:
Zhang Qingwei1, Zhu Liangming1, Dong Qi1, Sui Jiangbo1, Sun Mingwei1, Wang Jiangshan1, Yu Xiang2
Affiliation:
1. Naval Aviation University, Yantai 246001, China 2. College of Naval Architecture and Ocean Engineering, Naval University of Engineering, Wuhan 430033, China
Abstract
Targeting the problems of conventional active–passive hybrid vibration isolation systems, such as low output force, poor bearing capacity, large power loss and inability to withstand strong impacts, this paper proposes an active–passive hybrid vibration isolation system combining an electromagnetic actuator, rubber passive vibration isolator and magnetorheological damper. The overall design of the hybrid vibration isolation system is first introduced. Then, a two-dimensional electromagnetic frequency-domain simulation is carried out on the electromagnetic actuator to obtain the output characteristics. A three-dimensional modeling is conducted to simulate the electromagnetic–mechanical coupling in the time–frequency domain to obtain nephograms of the magnetic flux diffusion distribution and power loss. Then, a dynamic stiffness test is carried out on the rubber vibration isolator to obtain the dynamic stiffness characteristics and the damping angle curve. At the same time, an adaptive suppression filtered-x least mean square (ASFXLMS) algorithm is proposed to adjust the update of the control weight coefficients to ensure that the current signal does not exceed the effective operating range of the actuator when the electromagnetic actuator is subjected to strong external disturbances. Finally, a hybrid vibration isolation system-based active vibration isolation experimental platform is built, and multifrequency line spectra active–passive vibration isolation experiments are carried out. The results demonstrate that the hybrid vibration isolation system has good control effects in the time–frequency domain and shows good robustness when subjected to impact.
Funder
National Natural Science Foundation of China Naval Aviation University Independent Project Foundation
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Reference26 articles.
1. Kim, B., and Yoon, J.-Y. (2017). Enhanced Adaptive Filtering Algorithm Based on Sliding Mode Control for Active Vibration Rejection of Smart Beam Structures. Appl. Sci., 7. 2. Vibration isolation performance analysis of double layer vibration isolation system;Zhao;Chin. J. Ship Res.,2017 3. Li, D., He, Q., Yan, Z., and Li, X. (2018, January 14–16). Design of a linear electromagnetic actuator for active vibration control. Proceedings of the 2018 3rd International Conference on Mechanical, Control and Computer Engineering, Huhhot, China. 4. Michał, S., Mykola, K., Olegas, P., Adam, D., and Paulius, S. (2023). Research of vibrations effect on hydraulic valves in military vehicles. Def. Technol. 5. Adaptive tracking control for active suspension systems with non-ideal actuators;Pan;J. Sound Vib.,2017