Intra-Rater and Test–Retest Reliability of Barbell Force, Velocity, and Power during the Landmine Punch Throw Test Assessed by the GymAware Linear Transducer System

Author:

Oleksy Łukasz12ORCID,Kuchciak Maciej3ORCID,Bril Grzegorz4,Mika Anna5ORCID,Przydział Marta3,Pazdan-Śliż Iwona3,Kielnar Renata6,Racheniuk Henryk7,Adamska Olga8ORCID,Deszczyński Michał8

Affiliation:

1. Faculty of Health Sciences, Department of Physiotherapy, Jagiellonian University Medical College, 31-008 Kraków, Poland

2. Oleksy Medical & Sport Sciences, 37-100 Łańcut, Poland

3. Department of Physical Education, University of Rzeszow, 35-959 Rzezsów, Poland

4. Physiotherapy and Sports Centre, Rzeszow University of Technology, 35-959 Rzeszów, Poland

5. Institute of Clinical Rehabilitation, University of Physical Education in Kraków, 31-571 Kraków, Poland

6. Institute of Health Sciences, Medical College of Rzeszów University, 35-315 Rzeszów, Poland

7. Institute of Physiotherapy, Faculty of Physical Education and Physiotherapy, Opole University of Technology, 46-020 Opole, Poland

8. Department of Orthopaedics and Rehabilitation, Medical Faculty, Medical University of Warsaw, 02-091 Warsaw, Poland

Abstract

Background: Velocity-based training (VBT) requires measurement of the velocity at which the barbell is moved in the concentric phase with regard to different resistance exercises, which provides accurate, indirect estimations of 1 RM. However, for assessing punch performance, no study has been carried out to date. The purpose of this study was to analyse the reliability of the GymAware linear transducer for the measurement of barbell velocity during the landmine push throw (LPT) test using four loads. Methods: Twenty-five healthy, physically active male students, aged 24.13 ± 2.82 years, volunteered to take part in this study. The reliability of the LPT test was measured at two separate visits, with a 2-day interval between them. One series of the test protocol included four parts of the LPT test with progressively increasing loads (20, 25, 30, and 35 kg) and 5 min intervals for rests between loads. Results: For all four loads, excellent intra-rater and test–retest reliability was noted for the mean force variable (ICC = 0.97–0.99). Additionally, very strong and significant correlations were established between measurements (r = 0.96–0.99). Poor reliability was observed for barbell height and total work (ICC below 0.5). A trend of decreasing reliability was detected with increasing barbell load. Furthermore, measurements without the barbell throw were more reliable than those with it. Conclusions: These results support the use of the GymAware linear transducer to track barbell velocity during the LPT test. This device may have valuable practical applications for strength and conditioning coaches. Therefore, we suggest that the LPT assessed with the GymAware linear transducer may be a useful method for evaluating upper limb strength and power during boxing punches.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3