Transcatheter Aortic Valve Implantation with the Portico Valve: 2-Year Outcomes of a Multicenter, Real-World Registry

Author:

Didagelos Matthaios1ORCID,Ninios Vlasis2,Kakderis Charalampos1ORCID,Lakkas Lampros3,Kouparanis Antonios1,Nikas Dimitrios3ORCID,Naka Katerina K.3ORCID,Rammos Aidonis3ORCID,Zegkos Thomas1,Kamperidis Vasileios1ORCID,Ninios Ilias2,Evangelou Sotirios2,Tsalikakis Dimitrios G.4,Michalis Lampros3,Ziakas Antonios1

Affiliation:

1. 1st Cardiology Department, AHEPA University General Hospital, 54636 Thessaloniki, Greece

2. 2nd Cardiology Department, Interbalkan Medical Center, 55535 Thessaloniki, Greece

3. 2nd Cardiology Department, University Hospital of Ioannina, 45500 Ioannina, Greece

4. Department of Informatics and Telecommunications Engineering, University of Western Macedonia, 50100 Kozani, Greece

Abstract

Introduction: The self-expanding, resheathable, repositionable transcatheter aortic heart valve Portico is being used successfully for transcatheter aortic valve implantation procedures (TAVI) in patients with severe aortic stenosis. The aim of this study was to evaluate outcomes at 2 years after TAVI with the Portico valve. Methods: Multicenter registry of clinical, echocardiographic and survival data from consecutive patients treated with the Portico TAVI system (Abbott, Chicago, IL, USA) in three cath labs in Northern Greece and Epirus during 2017–2020. The primary end point was all-cause mortality at 24 months. Secondary end points included procedural outcomes (efficacy and safety) and echocardiographic measurements. Results: A total of 90 patients (81 ± 6 years, 50% females, mean age 81 ± 6 years) were included in the registry. The indication for implantation was severe, symptomatic aortic stenosis (NYHA III, IV) in eighty-two (91.1%) and degeneration of a prosthetic aortic valve in eight (8.9%) patients. All patients were categorized as high surgical risk (mean Logistic Euroscore 25.9 ± 10, Euroscore II 7.7 ± 4.4 and STS score 10.8 ± 8.9). The procedure was performed transfemorally in all patients, under general anesthesia in 95.6%, under TOE guidance in 21.1%, with native valve predilatation in 46.7%, and the “resheath” option was used in 31.1% of the cases. The implantation was successful in 97.8% and there was a need for a second valve in 2.2% of the cases. Complications included permanent pacemaker implantation (16.7%), access cite complications (15.6%), arrythmias (23.3%), paravalvular leak (moderate 7.8%, severe 1.1%), acute kidney injury (7.8%), no strokes and one death during the procedure. Aortic valve peak velocity, peak and mean pressure gradients, were significantly reduced after the procedure. All-cause mortality at 1, 12 and 24 months was 4.4%, 6.7% and 7.8%, respectively. Conclusions: TAVI with the Portico system comprises an effective and safe solution for the management of severe, symptomatic aortic stenosis in high-risk surgical patients.

Publisher

MDPI AG

Subject

Paleontology,Space and Planetary Science,General Biochemistry, Genetics and Molecular Biology,Ecology, Evolution, Behavior and Systematics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3