Abstract
The paper presents an experimental investigation of a steam ejector in a single-effect thermal vapor compression (S-TVC) desalination system driven by a low-temperature (below 100 °C) heat source. To investigate the performance of the steam ejector in the S-TVC desalination system, an experimental steam ejector system was designed and built. The influences of the nozzle exit position (NXP), operating temperatures, and the area ratio of the ejector (AR) on the steam ejector performance were investigated at primary steam temperatures ranging from 40 °C to 70 °C, and at secondary steam temperatures ranging from 10 °C to 25 °C. The experimental results showed that the steam ejector can work well in the S-TVC desalination system driven by a low-temperature heat source below 100 °C. The steam ejector could achieve a higher coefficient of performance (COP) by decreasing the primary steam temperature, increasing the secondary steam temperature, and increasing the AR. The steam ejector could also be operated at a higher critical condensation temperature by increasing the primary steam temperature and secondary steam temperature, and decreasing the AR. This study will allow S-TVC desalination to compete with adsorption desalination (AD).
Funder
Natural Science Foundation of Liaoning Province
National Natural Science Foundation of China
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
22 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献