Removal of Cr and Organic Matter from Real Tannery Wastewater via Fenton-like Process Using Commercial Nano-Scale Zero-Valent Iron

Author:

Vasquez Yaneth1ORCID,Franco Jair1,Vasquez Mario1,Agudelo Felipe1,Petala Eleni2,Filip Jan2,Galvis Jose3,Herrera Oscar1

Affiliation:

1. Faculty of Engineering and Basic Sciences, Convergence Science and Technology Cluster, Universidad Central, Bogotá 110311, Colombia

2. Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute (CATRIN), Palacký University, 77900 Olomouc, Czech Republic

3. School of Engineering, Science, and Technology, Universidad del Rosario, Bogotá 111711, Colombia

Abstract

The tannery wastewater from the tanning stage (TWT) comprises organic and Cr pollutants, which can adversely affect aquatic life and have carcinogenic effects. In this study, we investigated the performance of a Fenton-like process using commercial Nano-scale zero-valent iron (nZVI) for the simultaneous removal of Cr and organic matter from real TWT. We used an experimental design to select the principal operating parameters. A Plackett–Burman design identified variables for Cr-total and COD removal, followed by a central composite design (CC-D) to determine optimal variable levels. Finally, the response surface methodology (RSM) was used to find the optimum concentration of individual variables influencing Cr-total removal. Additionally, the effect of the leather-related, co-existing substances that influenced the efficiency of the process and the possibility of recycling nZVI were explored. The inclusion of nZVI was significantly more effective at removing both Cr-total and COD (97.3% ± 5.7% and 73.9% ± 9.1%, respectively), whereas the traditional Fenton process achieved lower removal rates (55.6% ± 10.0% for Cr-total and 34.8% ± 10.9% for COD). The optimal conditions for the Fenton-like process were nZVI/H2O2 = 1.05 w/w, and pH = 2.93. We obtained the best results during the first 5 min of the reaction, which increased after 48 h of agitation and subsequent neutralization. According to the results of four consecutive cycles, nZVI exhibited high reusability (97%) without compromising its adsorption potency. XPS analysis confirmed Cr removal through the adsorption mechanism on the nZVI surface. Hence, a Fenton-like process based on nZVI can be used as a promising alternative for treating organic and Cr wastewater.

Funder

Ministry of Science, Technology, and Innovation

Sistema General de Regalias

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3