Experimental Characterization and Acoustic Correction of a Multipurpose Performance Hall: The Italian Theatre “Cavallino Bianco”

Author:

De Giorgi Maria GraziaORCID,Congedo Paolo MariaORCID,Baglivo CristinaORCID,Bonomolo Marina,Milone DanieleORCID

Abstract

This study presents the retrofit acoustic dq1esign of the Italian theatre “Cavallino Bianco”. In its historical configuration, the hall had a curved roof with a pressed-plant fiber ceiling, which was demolished and replaced with a wooden roof without a false ceiling, leading to an increase in volume and a worsening of the reverberation time. This study proposed the realization of a wave ceiling and the application of sound-absorbing and reflecting panels on the walls, which have already been implemented. These modifications have affected the acoustic characterization of the theatre, as shown both through on-site measurements during the main construction phases and through numerical simulations. The reverberation time, clarity index, and speech transmission index (STI) are evaluated considering all the variations in the hall over different construction times, and the optimal solution is identified with regard to different specific uses. The final configuration with the new roof, by reducing the volume of the hall and using sound-absorbing materials, significantly reduces the reverberation time (e.g., at 2000 Hz, this reduction is from 2.33 to 1.47). In addition, the hall at full capacity with chairs and people shows evident improvement in terms of the clarity index, allowing the theatre to be used for a wide range of musical genres such as instrumental, symphonic, and opera performances. As regards the Combos 00 (concrete roof without vertical sound acoustic panels) and 01-a/b/c (wooden roof with draped curtains), the STI values are never lower than 0.42 and never higher than 0.70; therefore, the room never experiences poor or excellent conditions at any point. The Combos 01-a and 01-b, which have a non-performing C80, have a good STI index, confirming the difficulty of achieving a configuration that can be optimal a variety of uses. Combo 01 (wooden roof without vertical sound acoustic panels and no draped curtains), which has a good C80 value, presents a lower STI value, with an average performance. The STI values of Combo 02-a (characterized by wave false ceiling and vertical sound acoustic panels) are never lower than 0.52 and never higher than 0.60; therefore, neither poor nor excellent conditions are experienced in the room, but there is still a slight improvement over the combos 00 and 01.

Publisher

MDPI AG

Subject

Building and Construction,Civil and Structural Engineering,Architecture

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3