Experimental and Numerical Investigation of Airflow Organization in Modular Data Centres Utilizing Floor Grid Air Supply

Author:

Zhao Jingping1,Wu Jianlin1,Li Mengying1

Affiliation:

1. China Academy of Building Research Ltd., Beijing 100013, China

Abstract

Under the background of “dual carbon” development goals, the rapid expansion of internet data centers driven by advancements in 5G technology has led to increased energy consumption and elevated heat densities within the server rooms in these facilities. In this study, the modular data center is taken as the research object for the purpose of figuring out a way to improve the thermal environment of the computer room, reduce power consumption, and ensure the safe and stable running of servers. To this end, this study established an airflow organization model for the modular data center and verified this model through experimental methods. Computational Fluid Dynamics (CFD) simulations were employed to investigate the effects of raised floor height, floor opening rate, and cold/hot air channel closure on airflow organization. Furthermore, the efficiency of airflow organization was evaluated using entransy loss metrics. The results show that optimal airflow conditions are achieved when the height of the raised floor is 600–800 mm, the opening rate is 40%, and the combined opening is 40%. Additionally, the closure of either the cold channel or both the cold and hot channels significantly improves airflow performance. Specifically, cold channel closure is recommended for new data centers with underfloor air supply systems, while combined cold and hot channel closure is suitable for data centers with high power density and extended air supply distances.

Funder

Research and Application of Emergency and Safety Intelligent Management System

Publisher

MDPI AG

Reference21 articles.

1. Simulation and experimental research on the optimization of airflow organization and energy saving in data centers using air deflectors;Ma;Clean Energy Sci. Technol.,2024

2. Airflow uniformity optimization for modular data center based on the constructal T-shaped underfloor air ducts;Zhang;Appl. Therm. Eng.,2019

3. Experimental and numerical study of airflow distribution optimisation in high-density data centre with flexible baffles;Yuan;Build. Environ.,2018

4. A review on airflow management in data centers;Chu;Appl. Energy,2019

5. Schmidt, R.R. (2001, January 8–13). Effect of data center characteristics on data processing equipment inlet Temperatures. Proceedings of the InterPACK, Kauai, HI, USA.