Comparative Study on Behavior of Circular Axially Loaded CFDST Short Columns under Different Loading Arrangements

Author:

Yan Xi-Feng12ORCID,Lin Siqi3ORCID,He Mengnan4

Affiliation:

1. School of Civil Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China

2. Key Lab of Structural Engineering and Earthquake Resistance, Ministry of Education (XAUAT), Xi’an 710055, China

3. Key Laboratory of Urban Security and Disaster Engineering of Ministry of Education, Beijing University of Technology, Beijing 100124, China

4. Design Institute of Xi’an University of Architecture and Technology, Xi’an 710055, China

Abstract

So far, almost all studies have concentrated on the compressive performance of fully loaded concrete-filled double-skin steel tubular (CFDST) columns, but there have been few studies on partially loaded CFDST columns, and the difference in their behavior remains unclear. Thus, by focusing on the mechanical behavior of circular CFDST columns under different loading arrangements, this paper conducts a comparative study on circular axially loaded CFDST columns based on the author’s previous experimental results. A total of 28 experiments were conducted, in which 14 fully and 14 partially loaded specimens were tested. The influence law of crucial parameters on the compressive behavior of CFDST specimens with two different loading arrangements were compared and the results were discussed. It is shown that when the void ratio is 0 and 0.2, the ultimate strength of partially loaded CFDST columns is greater than that of fully loaded ones, but the results are opposite for the columns with the void ratios of 0.4 and 0.6. Subsequently, based on the experimental data, a finite element analysis (FEA) model was developed and used to ascertain the compressive behavior of CFDST columns with two different loading arrangements. The results suggested that, at the beginning of the loading phase, the outer tube of partially loaded CFDST columns provided a certain lateral confining stress to the concrete, while the lateral confining stress of fully loaded CFDST columns fluctuated around zero. The axial load of the inner tube of fully loaded CFDST columns first increased linearly and then remained almost unchanged. Due to the existence of friction, the inner tube of partially loaded CFDST columns also undertook a certain axial load, which first increased and then decreased to zero.

Publisher

MDPI AG

Subject

Building and Construction,Civil and Structural Engineering,Architecture

Reference47 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献