Evaluation of Phase Change Materials for Pre-Cooling of Supply Air into Air Conditioning Systems in Extremely Hot Climates

Author:

Masood Usman1ORCID,Haggag Mahmoud2ORCID,Hassan Ahmed2ORCID,Laghari Mohammad1ORCID

Affiliation:

1. Electrical and Communication Engineering Department, United Arab Emirates University, Al Ain P.O. Box 15551, United Arab Emirates

2. Architectural Engineering Department, United Arab Emirates University, Al Ain P.O. Box 15551, United Arab Emirates

Abstract

This research investigates the use of phase change materials (PCMs) in thermal energy storage (TES) unit-based cooling systems to increase the efficiency of air conditioners (ACs) by reducing the air inlet temperature. This study aims to evaluate different configurations of PCM enclosures, and different PCMs (paraffin and salt hydrate), by changing the speed of inlet air to achieve heat reduction of inlet air. The study includes experimental and simulation investigations. Every configuration simulates the hot-season atmospheric conditions of the UAE. A duct containing enclosures of paraffin RT-31 and salt hydrate (calcium chloride hexahydrate) was used for the simulation study using ANSYS/Fluent. A conjugate heat transfer model employing an enthalpy-based formulation is developed to predict the optimized PCM number of series and optimum airflow rate. Four designs of the AC duct were modelled and evaluated that contained one to four series of PCM containers subjected to different levels of supplied air velocities ranging from 1 m/s–4 m/s. The simulation study revealed that employing four series (Design 4) of PCM enclosures at a low air velocity of 1 m/s enhanced the pre-cooling performance and reduced the outlet air temperature to 33 °C, yielding a temperature drop up to 13 °C. The performance of salt hydrate (calcium chloride hexahydrate) was observed to be better than paraffin (RT-31) in terms of the cooling effect. Characterization of paraffin wax (RT-31) and salt hydrate was performed to establish the thermophysical properties. The experimental setup based on a duct with integrated PCM enclosures was studied. The experiment was repeated for three days as the repeatability test incorporating RT-31 as the PCM and a 3 °C maximum temperature drop was observed. The drop in the outlet air temperature of the duct system quantifies the cooling effect. Net heat reduction was around 16%.

Funder

UAE University

Publisher

MDPI AG

Subject

Building and Construction,Civil and Structural Engineering,Architecture

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3