Estimation of Durability of HC-550 Floor Slabs Based on Electrochemical Tests of Corrosion Rate of Reinforcement Strings in Concrete

Author:

Szweda Zofia1ORCID,Czachura Dominik2

Affiliation:

1. Department of Building Structures, Faculty of Civil Engineering, Silesian University of Technology, 44-100 Gliwice, Poland

2. Smart Solutions, Measurement Center 3D, 03-046 Warszawa, Poland

Abstract

The consequences of the loss of the load-bearing capacity due to the corrosion of prestressing steel can be much more dangerous than in the case of reinforced concrete structures, since failure can occur quite rapidly and without warning. A very important issue, therefore, is to determine the factors affecting the durability of prestressed structures exposed to aggressive agents, especially chloride ions. The aim of this study was to verify the protective properties of concrete of prefabricated HC-type prestressed concrete slabs in order to evaluate the possibility of their application in the ceilings of multilevel garages. In this paper, the corrosion rate of rebar steel in HC-550 floor slabs at a width of 1200 mm was estimated with nondestructive electrochemical methods: linear polarization and impedance spectroscopy. The general and mechanical properties of concrete prepared according to a formula in a laboratory and analogous concrete cut directly from the analyzed floor slabs were also studied. The porosity of concrete from these slabs was determined using X-ray-computed tomography for pore-related characterization. The values of the diffusion coefficient of chloride ions determined in previous works and the previously proposed model for the overexposure of the durability of floor slabs in chloride-containing environments were used to determine the durability of these slabs. Based on the empirical correlations adopted from the literature presenting the relationship of durability/adhesion over time and the corrosion parameters studied, a safe service life was determined at the nominal class of concrete equal to Δtcor.red = 30.48 years. In addition, in the case of discontinuities in the concrete structure, there may be a dangerous reduction in the time of corrosion initiation and a subsequent reduction in service life due to the loss of the adhesion of strut strands for up to 10.68 years of service life.

Funder

Silesian University of Technology

Publisher

MDPI AG

Subject

Building and Construction,Civil and Structural Engineering,Architecture

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3