Investigation of the Effect of Air Layer Thickness on the Thermal Performance of the PCM Integrated Roof

Author:

Bhamare Dnyandip K.1,Rathod Manish K.1ORCID,Banerjee Jyotirmay1ORCID,Arıcı Müslüm2ORCID

Affiliation:

1. Mechanical Engineering Department, Sardar Vallabhbhai National Institute of Technology, Surat 395007, Gujarat, India

2. Mechanical Engineering Department, Engineering Faculty, Kocaeli University, 41001 Kocaeli, Turkey

Abstract

Recently, Phase Change Materials (PCM) have become more prevalent in improving buildings’ thermal management. The relative location of the PCM layer is a valuable measure for assessing the thermal performance of building envelopes, in addition to meteorological circumstances and PCM qualities. The optimum air layers between the PCM layer and roof may significantly reduce energy consumption in buildings. In this regard, the influence of air gap layer thickness on the thermal performance of a PCM (HS 29) integrated roof of the test room is investigated experimentally. Experiments are carried out for an unconditioned test room located on the terrace of a laboratory in Surat, India, considering various air layer thickness values (0, 2, 4, and 6 cm) and a fixed PCM layer thickness. Different configurations within the research, including no- PCM and PCM with 0, 2, 4, and 6 cm air layer thickness, are investigated for the effects of diurnal change in room temperature. Results are evaluated based on the peak value, valley value temperatures of different roof layers, and an index (MKR, Measure of Key Response). It is observed that the maximum temperature difference between the PCM-integrated test room and the non-PCM test room is 4 °C to 7 °C. Results showed that, with a higher MKR index of 8.83, a PCM-integrated roof with a 2 cm air layer thickness could reduce the diurnal room temperature variations compared with the non-PCM test room. This conclusion from the current research demonstrates the significance of an air layer provided between the PCM layer and the roof of the building.

Publisher

MDPI AG

Subject

Building and Construction,Civil and Structural Engineering,Architecture

Reference33 articles.

1. International Energy Agency (2012). CO2 Emissions From Fuel Combustion: Highlights, IEA Publication.

2. (2013). 2013 April. Annual Energy Outlook 2013 with Projections to 2040.

3. Energy performance of building envelopes integrated with phase change materials for cooling load reduction in tropical Singapore;Lei;Appl. Energy,2016

4. Energy-saving owing to using PCM into buildings: Considering of hot and cold climate region;Dehkordi;Sustain. Energy Technol. Assess.,2022

5. BBland, A., Khzouz, M., Statheros, T., and Gkanas, E.I. (2017). PCMs for Residential Building Applications: A Short Review Focused on Disadvantages and Proposals for Future Development. Buildings, 7.