Summer Thermal Challenges in Emergency Tents: Insights into Thermal Characteristics of Tents with Air Conditioning

Author:

Xiang Mingli1,Liao Yuxuan1,Jia Yonghong2,Zhang Wentao1,Long Enshen13

Affiliation:

1. College of Architecture and Environment, Sichuan University, Chengdu 610065, China

2. Institute for Disaster Management and Reconstruction, Sichuan University, Chengdu 610207, China

3. MOE Key Laboratory of Deep Earth Science and Engineering, Sichuan University, Chengdu 610225, China

Abstract

Emergency tents face challenges in harsh weather conditions and sometimes require the use of air conditioning for indoor thermal environment control. However, their lightweight structure makes their control methods different from conventional buildings. This study focuses on the indoor thermal environment and thermal comfort of air-conditioned tents during summer. Through experimental measurements, this study captures the distribution of air temperatures and inner surface temperatures within a tent, thus providing an understanding of the characteristics of indoor thermal environment in air-conditioned settings. Additionally, the numerical simulations conducted using the ANSYS FLUENT 2021 R1 calculate the Predicted Mean Vote (PMV) and Predicted Percentage Dissatisfied (PPD), thus contributing to a detailed analysis of the indoor thermal comfort states. The experiment revealed that the mean radiative temperature (MRT) inside the tent can exceed the air temperature by more than 10 °C. Even when the air temperature is around 26 °C, the excessively high MRT can cause occupants to feel uncomfortable, with the PMV exceeding 1.4 and the PPD surpassing 50%. Furthermore, the high MRT results in an increased demand for cooling airflow, with the cooling loss through gaps becoming a significant part in the cooling load. To ensure a comfortable thermal environment, the air-conditioning set temperature needs to be adjusted according to the weather conditions. For instance, even at the same air temperature of 35 °C, when solar radiation increases from 400 W/m2 to 1000 W/m2, the set temperature needs to be reduced from 24.7 °C to 20.7 °C. The findings of this study provide an important reference for establishing summer air-conditioning strategies for emergency tents.

Funder

National Natural Science Foundation of China

Natural Science Foundation of Sichuan Province

Fundamental Research Funds for the Central Universities

Publisher

MDPI AG

Reference27 articles.

1. Selection of emergency shelter sites for seismic disasters in mountainous regions: Lessons from the 2008 Wenchuan Ms 8.0 Earthquake, China;Liu;J. Asian Earth Sci.,2011

2. Disaster management: Hierarchical structuring criteria for selection and location of temporary shelters;Nappi;Nat. Hazards,2015

3. Field Hospital in Disasters: A Systematic Review;Manoochehry;Trauma Mon.,2018

4. Thermal performance of shelter modelling: Improvement of temporary structures;Obyn;Energy Build.,2015

5. Poschl, R.A. (2017). Modelling the Thermal Comfort Performance of Tents Used in Humanitarian Relief, Loughborough University.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献