Abstract
With the advancement of information technology, energy consumption prediction models are widely used for various types of buildings (office, residential, and commercial buildings) as guidance during the design and management stages. This article will establish an efficient building energy consumption prediction model for hotel buildings. To achieve this, we collected 78 architectural drawings of high-rise hotel buildings to establish 6 kinds of typical energy consumption models in 2 standard floor layouts and 3 public area levels. Then, on this basis, we used the total energy consumption calculated by EnergyPlus as an indicator to conduct sensitivity analysis on geometric feature parameters, internal heat source parameters, and thermal parameters, respectively. Finally, we generated a building database with 5000 samples through the R programming language to calculate and verify the energy consumption. As a result, it was proved that the energy consumption of hotel buildings can be predicted accurately, and that quadratic polynomial regression, with the best accuracy and stability, is the most suitable optimization model for hotel energy consumption prediction in Guangzhou. These conclusions provide a good theoretical basis for the analysis, prediction, and optimization of energy consumption in high-rise hotel buildings in the future.
Funder
National Key Research and Development Project of China
Subject
Building and Construction,Civil and Structural Engineering,Architecture
Reference26 articles.
1. A review on buildings energy consumption information;Ortiz;Energy Build.,2008
2. Comparison of building energy demand for hotels, hospitals, and offices in Korea;Chung;Energy,2015
3. Li, Z. (2016). Research on Energy Consumption Quota and Energy Conservation Measures for Star-Level Hotel Buildings in Shandong Province. [Master’s Thesis, Shandong Jianzhu University].
4. Yu, S. (2018). Research on the Energy Supply Mode of the Coupling System between Renewable Energy and Energy Storage in Passive Ultra Low Energy Buildings. [Master’s Thesis, Shenyang Jianzhu University].
5. A performance comparison of multi-objective optimization-based approaches for calibrating white-box building energy models;Granada;Energy Build.,2020