Abstract
In Korean residential buildings, floor impact sounds were reduced over the past few decades mainly through a floating floor system. However, ceiling constructions for impact sound reduction have not been applied actively because of a lack of useful information. This study focuses on the effects of wall-to-wall supported ceilings (WSC), which are designed with construction discontinuities between concrete slabs and ceilings, and the damping caused by porous absorbers for impact sound insulation. To examine the impact sound insulation according to ceiling conditions, measurements were performed in 25 floor–ceiling assemblies. The results indicate that ceiling treatment is mostly useful in reducing the floor impact sound. The floor impact sound owing to the WSC decreased by 2–7 dB and 2–8 dB in terms of the single number quantity for the tapping machine and rubber balls, respectively, compared with representative existing housing constructions wherein ceilings were attached on wooden sticks. Furthermore, the reduction effect of the WSC appeared to be more profound when it was applied to the floor–ceiling assembly with poor impact sound insulation. Thus, the WSC can be used to enhance the impact of sound insulation of existing housings without major repairs of floor structural layers.
Funder
the Korean Agency for Infrastructure Technology Advancement
Subject
Building and Construction,Civil and Structural Engineering,Architecture
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献