Optimization of Double-Closed-Loop Control of Variable-Air-Volume Air-Conditioning System Based on Dynamic Response Model

Author:

Li Duanzheng1,Ahmat Mutellip1,Cao Hongqing2,Di Fankai1

Affiliation:

1. College of Electrical Engineering, Xinjiang University, Urumqi 830047, China

2. Xinjiang Special Equipment Inspection and Research Institute, Urumqi 830011, China

Abstract

Control strategies for variable-air-volume (VAV) air conditioning significantly affect both the air quality within buildings and the consumption of building energy. Current control techniques effectively regulate room temperature using feedback on temperature discrepancies, yet they also elevate the wear on terminal devices and boost the energy usage of the supply fan. In this paper, the hysteresis and inertia parameters of end air valves and supply fans under two seasonal conditions are derived from experimental data. Aiming at the problems of frequent switching of the end air valve, long total switching stroke, and high energy consumption of the air supply fan, a fuzzy PI regulation method is proposed based on the original pressure-independent series PI regulation, which effectively solves the above problems. Initially, data on how room temperature reacts to changes in air supply fan speed and the position of end air valves during winter and summer were gathered. Following model identification, parameters for various seasonal conditions were determined. Secondly, the roles of different components in the variable-air-volume regulation process were investigated. Investigations revealed that within pressure-independent variable-air-volume control, the supply fan and end air valve emerged as the primary subjects of the study. A double-closed-loop control with the speed control of the supply fan as the outer loop and the opening control of the end air valve as the inner loop was adopted. Compared with the traditional serial PI regulation, the room temperature error of this method was increased, but it reduced the total stroke of the valve by more than 43%, which greatly reduced the valve’s loss and noise and saved more than 2.7% of the energy consumption of the air supply fan.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3