Abstract
Cold-formed steel sections are becoming popular for different steel structures, because they have a high resistance against different straining actions, with a minimal weight compared with hard steel sections. Recently, perforated cold-formed steel (PCFS) sections have been used in many applications, such as perforated upright storage racks. Experimental research into the behavior of steel storage rack uprights subjected to axial compression is presented in this paper. First, tensile tests determined the material qualities of the cold-formed steel uprights. Then, seventeen perforated specimens were examined under axial compression, with five different cross-sections, three different web heights and thicknesses, and varying lengths. The study’s goals were to find out how perforations affect the performance and failure mode of steel storage rack uprights, to discuss the interaction of distortional and global buckling, and to verify the accuracy of using the direct strength method (DSM) for predicting the ultimate strength before failure in buckling interactions for perforated uprights. It was found that the failure modes of perforated specimens with stiffeners generally cannot be well predicted using the direct strength method. However, when the modifications proposed by Xianzhong Zhao et al. are used, the accuracy is acceptable.
Subject
Building and Construction,Civil and Structural Engineering,Architecture
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献