Modelling Framework for Reducing Energy Loads to Achieve Net-Zero Energy Building in Semi-Arid Climate: A Case Study

Author:

Azam Umair1,Farooq Muhammad1ORCID,Munir Muhammad Adeel1ORCID,Riaz Fahid2ORCID,Sultan Muhammad3ORCID,Rehman Ateekh Ur4ORCID,Imran Muhammad5ORCID

Affiliation:

1. Centre for Energy Research and Development (CERAD), Faculty of Mechanical Engineering, University of Engineering and Technology, Lahore 54890, Pakistan

2. Department of Mechanical Engineering, Abu Dhabi University, Abu Dhabi P.O. Box 59911, United Arab Emirates

3. Department of Agricultural Engineering, Bahauddin Zakariya University, Multan 60800, Pakistan

4. Department of Industrial Engineering, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia

5. Department of Mechanical, Biomedical and Design Engineering, College of Engineering and Physical Sciences, Aston University, Birmingham B4 7ET, UK

Abstract

Buildings consume a significant 40% of global energy, where, reducing the building energy consumption to a minimum, virtually zero, has become a thriving research area. Accordingly, this research aimed to determine and portray the huge potential of energy conservation in existing structures by making a retrofit at relatively low costs in finance strained economies. A walk-through of the survey of energy consuming appliances determined the energy consumption based on the power rating; the appliances were then virtually replaced and the reduced energy consumption was determined in terms of the cooling loads. Modelling these intervention using the hourly analysis program (HAP) showed significantly positive results. The pre- and post-retrofit model analysis of an institutional building in Pakistan exhibited significant potential for reducing the cooling load of 767 kW (218 TON) to 408 kW (116 TON) with an investment payback period of 2.5 years. The additional benefit is the reduced greenhouse gas (GHG) emissions which reduce the overall energy requirements. The study continues with the design of a solar energy source using the system advisor model (SAM) for the reduced energy demand of a retrofitted building. It is then concluded that using the available area, a solar energy source with a capital payback period of 5.7 years would bring an institutional building within its own energy footprint making it a net-zero building, since it will not be consuming energy from any other source outside of its own covered area. The study has the limitation to exposure and climate related conditions. In addition, the decline in heating and cooling loads represents model values which may vary when calculated after an actual retrofit for the same structure due to any site related issues.

Funder

King Saud University, Riyadh, Saudi Arabia

Abu Dhabi University’s Office of Research and Sponsored Programs

Publisher

MDPI AG

Subject

Building and Construction,Civil and Structural Engineering,Architecture

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司