Dynamic Response Modeling of Mountain Transmission Tower-Line Coupling System under Wind–Ice Load

Author:

Song Haoran12ORCID,Li Yingna12

Affiliation:

1. Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China

2. Computer Technology Application Key Lab of the Yunnan Province, Kunming 650500, China

Abstract

Transmission lines have the characteristics of being tall tower structures with a large span distribution of transmission lines that are sensitive to external loads such as wind and ice, and belong to strong, nonlinear, complex, rigid-flexible coupling systems. The force process of the tower-line structure is a combination of instantaneous and continuously stressed, so it is not accurate to judge the safety of the transmission line based only on the operation status of the transmission tower or the conductor. In this paper, a finite element model of three towers and two lines with large span and large elevation differences is established by taking into account the tower-line coupling system. From the static point of view, the static axial force of a single tower and the contribution rate of wind and ice load are analyzed, and the ultimate bearing capacity of a tension-type electric tower is obtained by considering the bending effect and critical initial defects. From the perspective of transient dynamic response, the displacement of the tower-line coupling system under wind–ice load is calculated, and the force characteristics and force transmission process of the straight tower under wind–ice load are observed. Multiple comparison models are set up to compare and analyze the sway and tension under large span and large elevation differences, and the maximum icing thickness of each group model is obtained by repeated trials. The experimental results show that under the tower-line coupling system, the contribution of wind load to the axial force of the main material is 72.92%, and the contribution of wind–ice load to the axial force of main material is 27.6%. The maximum increase tension under transient ice-off effect is 59.58%, the ultimate force of the tension tower is 545.5 kN, and the maximum icing thickness of the transmission line under large span and large elevation differences is 28.7 cm, which is slightly larger than the design icing thickness. In conclusion, this paper can provide reference for the construction of mountain transmission towers, power safety inspection, and line health status assessment.

Funder

National Natural Science Foundation of China

Yunnan Provincial Department of Science and Technology

Publisher

MDPI AG

Subject

Building and Construction,Civil and Structural Engineering,Architecture

Reference29 articles.

1. Progress in mechanical modeling of power transmission pylon systems;Bo;Eng. Mech.,2021

2. Design and wind tunnel testing of an aeroelastic model for the 1000 kV Han River crossing EHV transmission tower system;Zhengliang;Chin. Acad. J. Abstr.,2008

3. FE Simulation of Transmission Tower;Eltaly;Adv. Civ. Eng.,2014

4. Experimental and numerical study on the responses of a transmission tower to skew incident winds;Deng;J. Wind. Eng. Ind. Aerodyn.,2016

5. A method for analyzing stability of tower-line system under strong winds;He;Adv. Eng. Softw.,2019

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3