Affiliation:
1. College of Urban Construction, Nanjing Tech University, Nanjing 210009, China
2. Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei 230026, China
Abstract
A Trombe wall is a widely applied heating system that has a single function. An interesting thing is that both the solar heat and UV light received by a Trombe wall have an air sterilization effect. Here, the air sterilization and thermal performances of a Trombe wall in different cities were investigated based on an established heat and mass transfer model. The main results were as follows: (1) UV dose accumulation and high temperature were the most important factors that affect the UV and thermal sterilization performance, respectively. The Trombe wall had the thermal characteristics of high accumulation of UV doses in the morning and afternoon and a high temperature level at noon, which was a good match with the UV and thermal sterilization process. (2) A typical sterilization process in a Trombe wall was divided into three areas: the UV inactivation area, UV and thermal inactivation area and UV inactivation area. (3) The weather conditions played an important role in the sterilization performance. UV sterilization was dominant in cloudy weather, and thermal sterilization was dominant in sunny weather. (4) In Nanjing, Shanghai, Xining and Guangzhou, the average daily clean air volumes in heating months were 39.4, 33.5, 32.2 and 39.8 m3/m2, respectively. (5) When the wall height increased from 1.5 m to 3.5 m, the average daily clean air volume in heating months increased from 31.7 to 43.6 m3/m2.
Funder
Natural Science Foundation of Jiangsu Province
National Natural Science Foundation of China
Reference41 articles.
1. The relationship between indoor air quality (IAQ) and perceived air quality (PAQ)—A review and case analysis of Chinese residential environment;Pei;Energy Built Environ.,2022
2. Experimental exploration on airtightness performance of residential buildings in the hot summer and cold winter zone in China;Zheng;Build. Environ.,2022
3. Optimizing chemisorption based direct air capture unit efficiency in HVAC systems: A study on the impact of DAC location and adsorption conditions as a response to the climate crisis and indoor air quality;Abdullatif;Energy Convers. Manag.,2023
4. Distribution characteristics, growth, reproduction and transmission modes and control strategies for microbial contamination in HVAC systems: A literature review;Liu;Energy Build.,2018
5. Mohamed, A.-M.O., Paleologos, E.K., and Howari, F.M. (2021). Pollution Assessment for Sustainable Practices in Applied Sciences and Engineering, Butterworth-Heinemann.