Sensor Incipient Fault Impacts on Building Energy Performance: A Case Study on a Multi-Zone Commercial Building

Author:

Li Yanfei1,Im Piljae2,Lee Seungjae3,Bae Yeonjin1,Yoon Yeobeom2,Lee Sangkeun4

Affiliation:

1. Electrification and Energy Infrastructures Division, Building Technologies Research and Integration Center, Oak Ridge National Laboratory, 1 Bethel Valley Rd, Oak Ridge, TN 37830, USA

2. Buildings and Transportation Science Division, Building Technologies Research and Integration Center, Oak Ridge National Laboratory, 1 Bethel Valley Rd, Oak Ridge, TN 37830, USA

3. Department of Civil and Mineral Engineering, University of Toronto, 35 St. George St, Toronto, ON M5S 1A4, Canada

4. Computer Science and Mathematics Division, Oak Ridge National Laboratory, 1 Bethel Valley Rd, Oak Ridge, TN 37830, USA

Abstract

Existing studies show sensor faults/error could double building energy consumption and carbon emissions compared with the baseline. Those studies assume that the sensor error is fixed or constant. However, sensor faults are incipient in real conditions and there were extremely limited studies investigating the incipient sensor fault impacts systematically. This study filled in this research gap by studying time-developing sensor fault impacts to rule-based controls on a 10-zone office building. The control sequences for variable air volume boxes (VAV) with an air handling unit (AHU) system were selected based on ASHRAE Guideline 36-2018: High-Performance Sequences of Operation for HVAC Systems. Large-scale simulations on cloud were conducted (3600 cases) through stochastic approach. Results show (1) The site energy differences could go −3.3% lower or 18.1% higher, compared with baseline. (2) The heating energy differences could go −66.5% lower or 314.4% higher, compared with baseline. (3) The cooling energy differences could go −11.5% lower or 65.0% higher, compared with baseline. (4) The fan energy differences could go 0.15% lower or 6.9% higher, compared with baseline.

Funder

field work proposal CEBT105 under DOE BTO activity

Publisher

MDPI AG

Subject

Building and Construction,Civil and Structural Engineering,Architecture

Reference29 articles.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Improving the PCA-based Chiller Sensor Fault Diagnosis with Relative Contribution;2024 5th International Conference on Computer Engineering and Application (ICCEA);2024-04-12

2. Occupancy schedule development and its effect on OpenStudio prototype college building model;Science and Technology for the Built Environment;2024-03-11

3. Development of Building Design Optimization Methodology: Residential Building Applications;Buildings;2023-12-31