The paper presents a full-scale blast testing experimental campaign conducted on an energyabsorbing connector comprising thin-walled inversion tubes as kernel elements mounted in a façade protective panel. LS-DYNA finite element predictions of the global and local deformation/inversion of the panel/connectors compared reasonably well with the experimental observations. After validation, the numerical model was used to analyze the response of a simple idealized reinforced concrete structure under three blast-loading scenarios: the first two scenarios produce, approximately, the same impulse but are significantly different in terms of load duration and overpressures, and represent a far-field and a near-field scenario (1600 kg TNT at 20 m (i) and 150 kg TNT at 5 m (ii), respectively); the third scenario is more demanding, and consists in a half standoff distance of the second (150 kg TNT at 2.5 m (iii)). These numerical simulations allow to assess the effect of standoff distance and blast loading on the effectiveness of the protective system. One may conclude that the introduction of EACs strongly limits the forces imparted to the protected structure, reducing significantly the corresponding energy absorption demand. Comparing the energy absorbed by the structure in different scenarios, with and without the protective system (8 × ϕ64 × 2 mm), one can see that these reductions can reach, respectively 67%, 72% and 68% in the far-field, near-field and very near-field explosions.
Funder
NATO Counter Improvised Explosive Device Centre of Excellence
the Portuguese funding institution FCT - Fundação para a Ciência e Tecnologia
Subject
Building and Construction,Civil and Structural Engineering,Architecture
Reference21 articles.
1. Explosion and Impact Resistance of Ultra High Performance Fibre Reinforced Concrete;Barnett;Concrete,2007
2. Behaviour of ultra high performance fibre reinforced concrete columns subjected to blast loading;Xu;Eng. Struct.,2016
3. Bazan, M., and Oswald, C.J. (2010). Blast Design of Reinforced Concrete and Masonry Components Retrofitted with FRP, Protection Engineering Consultants LLC.
4. ASCE (2010). Design of Blast-Resistant Buildings in Petrochemical Facilities, American Society of Civil Engineers. [2nd ed.].
5. Use of Precast Concrete Walls for Blast Protection of Steel Stud Construction;Naito;J. Perform. Constr. Facil.,2011
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献