Abstract
The main coolant system (MCS) plays a vital role in the stability and reliability of a nuclear power plant. However, human errors and natural disasters may cause some reactor coolant system components to fail, resulting in severe consequences such as nuclear leakage. Therefore, it is crucial to perform a resilience analysis of the MCS, to effectively reduce and prevent losses. In this paper, a resilience importance measure (RIM) for performance loss is proposed to evaluate the performance of the MCS. Specifically, a loss importance measure (LIM) is first proposed to indicate the component maintenance priority of the MCS under different failure conditions. Based on the LIM, RIMs for single component failure and multiple component failures were developed to measure the recovery efficiency of the system performance. Finally, a case study was conducted to demonstrate the proposed resilience measure for system reliability. Results provide a valuable reference for increasing the system security of the MCS and choosing the appropriate total maintenance cost.
Funder
National Natural Science Foundation of China
Ministry of Education's Humanities and Social Sciences Planning Fund
Subject
General Mathematics,Engineering (miscellaneous),Computer Science (miscellaneous)
Cited by
26 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献