Affiliation:
1. College of Ocean Science and Engineering, Shanghai Maritime University, Shanghai 201306, China
Abstract
The impact of wave-induced forces on the integrity of stationary oscillating water column (OWC) devices is essential for ensuring their structural safety. In our study, we built a three-dimensional numerical model of an OWC device using the computational fluid dynamics (CFDs) software OpenFOAM-v1912. Subsequently, the hydrodynamic performance of the numerical model is comprehensively validated. Finally, the hydrodynamic performance data are analyzed in detail to obtain meaningful conclusions. Results indicate that the horizontal wave force applied to the OWC device is approximately 6.6 to 7.9 times greater than the vertical wave force, whereas the lateral wave force is relatively small. Both the horizontal and vertical wave forces decrease as the relative water depth increases under a constant wave period and height. In addition, the highest dynamic water pressure is observed at the interface between the water surface and device, both within and outside the front wall of the gas chamber. The dynamic water pressure at different locations on the front chamber increases and subsequently decreases as the wave frequency increases.
Funder
National Natural Science Foundation of China
Science and Technology Commission of Shanghai Municipality