Abstract
Concrete-filled composite columns are widely used in the construction industry, exploiting the benefits of combining steel and concrete, providing, for instance, high load-bearing capacities and enhanced fire resistance. These solutions are extensively used in high-rise buildings and/or when high fire resistance performance requirements are imposed. In this exploratory research, a new type of concrete-filled composite column is investigated using fire resistance tests. Promoting the use of cold-formed steel products and developing innovative solutions for low-rise buildings with lower passive fire protection requirements led to the solutions presented in this research. Hence, a set of fire-resistance tests were undertaken on concrete-filled closed built-up cold-formed steel columns, where single cold-formed steel shapes are combined and fastened to create a box-shaped cross-section. The experimental results were then compared with the corresponding bare steel solutions to assess, in detail, the observed enhancements. Additionally, the effect of restraint on thermal elongation was assessed.
Funder
Fundação para a Ciência e Tecnologia
Subject
General Materials Science
Cited by
21 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献