Author:
Manea Andrei,Gorjanu Teodora,Lazeanu Andreea,Dumitran Laurentiu Marius
Abstract
Power transformers are still equipment of primary importance within power grids. The recent paradigm changes registered in the field of energy require the interconnection of electrical grids of much larger areas, even up to the level of an entire continent. In this context, knowing the state of the electrical equipment and that of the power transformers is an essential aspect to ensure safe operation conditions. The present work is related to the vulnerability of the oil–paper insulation systems of power transformers to different aging factors and their quick degradation under certain conditions. In this regard, the study proposed in this paper considers the measurement of DC resistivity on mineral oil samples contaminated with small amounts of accelerated aging oil under the action of high-strength electric field and partial discharges. In the absence of standardized procedures for accelerated electrical aging of mineral oil, an original method presented and discussed in previous articles is used. The obtained results clearly indicate that under the action of electrical stress, the mineral oil resistivity decreases significantly, showing that the oil’s electric properties worsen.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction
Reference24 articles.
1. (2022, December 19). North American Electric Reliability Corporation, Special Report: Spare Equipment Database System. Available online: https://drosheim.files.wordpress.com/2012/10/sedtf_special_report_october_2011.pdf.
2. Schwarz, R., and Muhr, M. (2008, January 21–24). Diagnostic Methods for Transformers. Proceedings of the International Conference on Condition Monitoring and Diagnosis, Pekin, China.
3. Saha, T.K., Pradhan, M.K., and Yew, J.H. (2007, January 24–28). Optimal Time Selection for the Polarisation and Depolarisation Current Measurement for Power Transformer Insulation Diagnosis. Proceedings of the Power Engineering Society General Meeting, Tampa, FL, USA.
4. Dielectric Response Methods for Diagnostics of Power Transformers;Gubanski;CIGRE,2002
5. Asset-Management of Transformers Based on Condition Monitoring and Standard Diagnosis;Zhang;IEEE Electr. Insul. Mag.,2008
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献