Abstract
Countercurrent flow limitation (CCFL) refers to an important class of gravity-induced hydrodynamic processes that impose a serious restriction on the operation of gas–liquid two-phase systems. In a nuclear power plant, CCFL may occur in the liquid level measurement system where an orifice is applied in the pipeline, which may introduce error into the level measurement system. CCFL can occur in horizontal, vertical, inclined, and even much more complicated geometric patterns, and the hot-leg channel flow passage has been widely investigated; however, a pipeline with variable cross-sections, including an orifice, has not yet been investigated. An experimental investigation has been conducted in order to identify the phenomenon, pattern, and mechanism of CCFL onset in this type of geometry. Both visual and quantified experiments were carried out. A high-speed camera was applied to capture the flow pattern. Visual experiments were implemented at atmospheric pressure, while quantified pressurizer experiments were implemented at higher pressures. It was determined that if the condensate drainage is low and the liquid level is also low, with a stable stratified flow upstream of the orifice, there is no oscillation of the differential pressure. However, at higher condensate drainage levels, when the liquid level increases, a stratified wavy flow occurs. One of these waves can suddenly rise upstream of the orifice to choke it, which subsequently gives rise to differential pressure across the orifice, with periodic variation. This pattern alternately features stratified flow, stratified wavy flow, and slug flow, which indicates the occurrence of CCFL. The CCFL occurring under these experimental conditions can be expressed as a Wallis type correlation, where the coefficients m and C are 0.682 and 0.601, respectively.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction
Reference24 articles.
1. Mostafa Ghiaasiaan, S. (2007). Two-Phase Flow, Boiling and Condensation: In Conventional and Miniature Systems, Cambridge University Press.
2. Wallis, G.B. (1969). One-Dimensional Two-Phase Flow, McGraw Hill.
3. Bankoff, S.G., and Lee, S.C. (1983). A Critical Review of the Flooding Literature, NUREG/CR-3060.
4. Behaviour of Liquid Films and Flooding in Counter-Current Two-Phase Flow—Part 1. Flow in Circular Tubes;Suzuki;Int. J. Multiph. Flow,1977
5. Effect of Tube Diameter on Flooding;Vijayan;Int. J. Multiph. Flow,2001
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献