Abstract
This study investigates the technical and economic feasibility of replacing throttling valves with smale-scale, oil-free turbomachinery in industrial steam networks. This is done from the perspective of the turbomachine, which has to be integrated into a new or existing process. The considered machines have a power range of P=[0.5,…,250 kW] and have been designed using real industrial data from existing processes. Design guidelines are developed, which take into account the thermodynamic process as well as engineering aspects of such a turbomachine. The results suggest that steam conditioning prior to heat exchange could be completed by small expanders to produce mechanical work, reducing exergy destruction and improving site-wide energy efficiency compared to throttling valves. Cost estimates for such machines are presented, which serve as a basis for case-specific investment calculations. The resulting payback times of less than 18 months highlight the economic potential such solutions.
Funder
Innosuisse - Schweizerische Agentur für Innovationsförderung
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献