Reliability of Maximal Strength and Peak Rate of Force Development in a Portable Nordic Hamstrings Exercise Device

Author:

Costa Júlio A.1ORCID,Spyrou Konstantinos123ORCID,Sancho António4,Reis Joana F.145ORCID,Brito João1ORCID

Affiliation:

1. Portugal Football School, Portuguese Football Federation (FPF), 1495-433 Cruz Quebrada, Portugal

2. UCAM Research Center for High Performance Sport, UCAM Universidad Católica de Murcia, 30107 Murcia, Spain

3. Facultad de Deporte, UCAM Universidad Católica de Murcia, 30107 Murcia, Spain

4. Faculdade de Motricidade Humana, Universidade de Lisboa, 1495-751 Lisboa, Portugal

5. Interdisciplinary Center for the Study of Human Performance (CIPER), Faculdade de Motricidade Humana, Universidade de Lisboa, 1495-751 Lisboa, Portugal

Abstract

The Nordic hamstring exercise (NHE) is a very popular exercise used to improve eccentric strength and prevent injuries. The aim of this investigation was to assess the reliability of a portable dynamometer that measures maximal strength (MS) and rate of force development (RFD) during the NHE. Seventeen physically active participants (34.8 ± 4.1 years; n = 2 women and n = 15 men) participated. Measurements occurred on two different days separated by 48–72 h. Test–retest reliability was calculated for bilateral MS and RFD. No significant test–retest differences were observed in NHE (test–retest [95% CI, confidence interval]) for MS [−19.2 N (−67.8; 29.4); p = 0.42] and RFD [−70.4 N·s−1 (−178.4; 37.8); p = 0.19]. MS showed high reliability (intraclass correlation coefficient [ICC] [95% CI], =0.93 [0.80–0.97] and large within-subject correlation between test and retest [r = 0.88 (0.68; 0.95)]. RFD displayed good reliability [ICC = 0.76 (0.35; 0.91)] and moderate within-subject correlation between test and retest [r = 0.63 (0.22; 0.85)]. Bilateral MS and RFD displayed a coefficient of variation of 3.4% and 4.6%, respectively, between tests. The standard error of measurement and the minimal detectable change for MS was 44.6 arbitrary units (a.u.) and 123.6 a.u., and 104.6 a.u. and 290.0 a.u. for peak RFD. This study shows that MS and RFD can be measured for NHE using a portable dynamometer. However, not all exercises are suitable to apply to determine RFD, so caution must be taken when analyzing RFD during NHE.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3