Digital Evaluation of the Accuracy of Computer-Guided Dental Implant Placement: An In Vitro Study

Author:

Kim Seong-Min,Son KeunbadaORCID,Kim Duk-Yeon,Lee Kyu-Bok

Abstract

Compared to traditional implant surgical guides, computer-assisted implant surgical guides can be considered for positioning implants in the final prosthesis. These computer-assisted implant surgical guides can be easily fabricated with personal 3D printers after being designed with implant planning CAD software. Although the accuracy of computer-assisted implant surgical guides fabricated using personal 3D printers is an important factor in their clinical use, there is still a lack of research examining their accuracy. Therefore, this study evaluated the accuracy of computer-assisted implant surgical guides, which were designed using two implant planning CAD software programs (Deltanine and R2gate software) and fabricated with personal 3D printers using a non-radiographic method. Amongst the patients who visited Kyungpook National University Dental Hospital, one patient scheduled to undergo surgery of the left mandibular second premolar was randomly selected. Twenty partially edentulous resin study models were produced using a 3D printer. Using the Deltanine and R2gate implant planning CAD software, 10 implant surgical guides per software were designed and produced using a personal 3D printer. The implants (SIII SA (Ø 4.0, L = 10 mm), Osstem, Busan, Korea) were placed by one skilled investigator using the computer-assisted implant surgical guides. To confirm the position of the actual implant fixture, the study models with the implant fixtures were scanned with a connected scan body to extract the STL files, and then overlapped with the scanned file by connecting the scan body-implant fixture complex. As a result, the mean apical deviation of the Deltanine and R2gate software was 0.603 ± 0.19 mm and 0.609 ± 0.18 mm, while the mean angular deviation was 1.97 ± 0.84° and 1.92 ± 0.52°, respectively. There was no significant difference between the two software programs (p > 0.05). Thus, the accuracy of the personal 3D printing implant surgical guides is in the average range allowed by the dental clinician.

Funder

Korea Institute for Advancement of Technology (KIAT)

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3