Influence of Section Thickness on the Accuracy and Specificity of Histometric Parameters Using Confocal Laser Scanning Microscopy in a Canine Model of Experimental Peri-Implantitis—A Proof of Concept

Author:

Boldeanu Lucia-Camelia1,Popa-Wagner Aurel23ORCID,Boariu Marius4,Stratul Stefan-Ioan1,Rusu Darian1,Vela Octavia1,Roman Alexandra5ORCID,Surlin Petra6,Kardaras Georgios1,Chinnici Salvatore1ORCID,Vaduva Adrian78ORCID

Affiliation:

1. Department of Periodontology, Faculty of Dental Medicine, Anton Sculean Research Center for Periodontal and Peri-Implant Diseases, “Victor Babes” University of Medicine and Pharmacy, 300041 Timisoara, Romania

2. Department of Neurology, Chair of Vascular Neurology and Dementia, University Hospital Essen, 45147 Essen, Germany

3. Center for Experimental and Clinical Medicine, University of Medicine and Pharmacy Craiova, 200349 Craiova, Romania

4. Department of Endodontics, Faculty of Dental Medicine, TADERP Research Center, “Victor Babes” University of Medicine and Pharmacy, 300041 Timisoara, Romania

5. Applicative Periodontal Regeneration Research Unit, Department of Peridontology, Faculty of Dental Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj Napoca, Romania

6. Department of Periodontology, Faculty of Dental Medicine, University of Medicine and Pharmacy, 200349 Craiova, Romania

7. Department of Pathology, Faculty of Medicine, ANAPATMOL Research Center, “Victor Babes” University of Medicine and Pharmacy, 300041 Timisoara, Romania

8. County Emergency Hospital, L. Rebreanu Street, nr. 156, 300723 Timisoara, Romania

Abstract

Objectives: Tissue breakdown was assessed by confocal laser scanning microscopy (CLSM) using autofluorescence around implants with ligatures, on a dog hemimandible. Influence of section thickness on the accuracy of histometrical observations was also evaluated, in comparison with thin sections in light microscopy. Material and Methods: Three months after tooth extraction, implants were placed. Two months after abutment placement, ligatures were placed with no plaque control. 11 months post-implantation, the animal was sacrificed. Undecalcified thin (30 µm) sections were cut, stained and evaluated by light microscopy to be used as a reference. Additional sections were performed, so that another pair of unstained thick sections resulted (250–300 µm). Tissue loss was assessed using histomorphometric parameters under CLSM and was compared to the light microscopy reference ones. Results: Morphometry confirmed tissue loss more pronounced on the “thick” and quick sections, when compared to the time-consuming and technique-sensitive “thin” ones. Conclusions: Within the limits of the present study, the adequacy of histometrical observations under CLSM reveal commensurable information about soft-tissue-bone-implant details, when compared to traditional light microscopy histological protocols. The CLSM investigation may seem demanding, yet the richness of data acquired may justify this approach, provided seatbacks caused by improper manipulation of “thick” sections are avoided.

Funder

UEFISCDI, under the umbrella of the EuroNanoMed project