Abstract
Background: This study was to evaluate the correlation of the hypoperfusion intensity ratio (HIR) with the collateral score from multiphase computed tomography angiography (mCTA) among patients with large vessel stroke. Method: From February 2019 to May 2020, we retrospectively reviewed the patients with large vessel strokes (intracranial carotid artery or proximal middle cerebral artery occlusion). HIR was defined as a Tmax > 10 s lesion volume divided by a Tmax > 6 s lesion volume, which was calculated by automatic software (Syngo.via, Siemens). The correlation between the HIR and mCTA score was evaluated by Pearson’s correlation. The cutoff value predicting the mCTA score was evaluated by receiver operating characteristic analysis. Result: Ninety-four patients were enrolled in the final analysis. The patients with good collaterals had a smaller core volume (37.3 ± 24.7 vs. 116.5 ± 70 mL, p < 0.001) and lower HIR (0.51 ± 0.2 vs. 0.73 ± 0.13, p < 0.001) than those with poor collaterals. A higher HIR was correlated with a poorer collateral score by Pearson’s correlation. (r = −0.64, p < 0.001). The receiver operating characteristic (ROC) analysis suggested that the best HIR value for predicting a good collateral score was 0.68 (area under curve: 0.82). Conclusion: HIR is a good surrogate of collateral circulation in patients with acute large artery occlusion.