Automatic Calibration of the Step Length Model of a Pocket INS by Means of a Foot Inertial Sensor

Author:

Bousdar Ahmed DinaORCID,Diaz Estefania Munoz,García Domínguez Juan JesúsORCID

Abstract

All non-foot-mounted inertial localization systems have a common challenge: the need for calibrating the parameters of the step length model. The calibration of the parameters of a step length model is key for an accurate estimation of the pedestrian’s step length, and therefore, for the accuracy of the position estimation. In a previous work, we provided a proof of concept on how to calibrate step length models with a foot inertial navigation system (INS), i.e., an INS based on an inertial measurement unit (IMU) mounted on the upper front part of the foot. The reason is that the foot INS does not require calibration thanks to the implementation of the strapdown algorithm. The goal of this article is to automatically calibrate the parameters of a step length model of the pocket INS by means of the foot INS. The step length model of the pocket INS has two parameters: the slope and offset of a first-order linear regression that relates the amplitude of the thigh pitch with the user’s step length. Firstly, we show that it is necessary to estimate the two parameters of the step length model. Secondly, we propose a method to automatically estimate these parameters by means of a foot INS. Finally, we propose a practical implementation of the proposed method in the pocket INS. We evaluate the pocket INS with the proposed calibration method and we compare the results to the state of the art implementations of the pocket INS. The results show that the proposed automatic calibration method outperforms the previous work, which proves the need for calibrating all the parameters of the step length model of the pocket INS. In this work, we conclude that it is possible to use a foot INS to automatically calibrate all parameters of the step length model of the pocket INS. Since the calibration of the step length model is always needed, our proposed automatic calibration method is a key enabler for using the pocket INS.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3